WebGraph-Thermo-Hygrometer-US-MIB :: wtWebioAn1MailEnable

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › WebGraph-Thermo-Hygrometer-US-MIB › wtWebioAn1MailEnable

wtWebioAn1MailEnable

Module: WebGraph-Thermo-Hygrometer-US-MIB

OID (symbolic): WebGraph-Thermo-Hygrometer-US-MIB::wtWebioAn1MailEnable

OID (numeric): 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.4

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-write

Description: Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable

What is wtWebioAn1MailEnable?

The bit that enables the device to actually send outgoing alert/report emails (Set this bit to enable the sending of mails, per the source DESCRIPTION). Note: despite its Webio/An1 naming (apparently carried over from a different W&T analog-input product line's MIB rather than renamed for this Thermo-Hygrometer module), it sits at { wtWebGraphThermHygroMail 4 } directly between MailServer and MailAuthentication, so it is genuinely this device's global mail-enable switch, not a leftover from another device.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.4
snmpwalk -v2c -c public <target> WebGraph-Thermo-Hygrometer-US-MIB::wtWebioAn1MailEnable

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.4.1
snmpget -v2c -c public <target> WebGraph-Thermo-Hygrometer-US-MIB::wtWebioAn1MailEnable.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.4.1 s <value>

Start monitoring WebGraph networked thermo-hygrometer environmental sensor appliance (temperature/humidity reading/alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WebGraph-Thermo-Hygrometer-US-MIB::wtWebioAn1MailEnable OID value, configure state conditions and alerts, and monitor any WebGraph networked thermo-hygrometer environmental sensor appliance (temperature/humidity reading/alarm status) from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5040wutCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1wtComServerCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1.2wtWebioWebGraph-8xThermometer-US-MIB
1.3.6.1.4.1.5040.1.2.9wtWebGraphThermHygroWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3wtWebGraphThermHygroConfigWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1wtWebGraphThermHygroDeviceWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.3wtWebGraphThermHygroBasicWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.3.3wtWebGraphThermHygroMailWebGraph-OLD-Thermo-Hygrometer-US-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5040.1.2.9.3.1.3.3.4wtWebioAn1MailEnableWebGraph-Thermo-Hygrometer-US-MIB