wtWebGraphThermHygroMailAuthentication

Module: WebGraph-Thermo-Hygrometer-US-MIB

OID (symbolic): WebGraph-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroMailAuthentication

OID (numeric): 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.5

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-write

Description: Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication

What is wtWebGraphThermHygroMailAuthentication?

Selects the authentication mode for outgoing mail: plain SMTP with no authentication, ESMTP with authentication, or POP3-before-SMTP; must match what the configured mail server requires or outgoing alert mail will fail.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.5
snmpwalk -v2c -c public <target> WebGraph-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroMailAuthentication

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.5.1
snmpget -v2c -c public <target> WebGraph-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroMailAuthentication.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.5.1 s <value>

Start monitoring WebGraph networked thermo-hygrometer environmental sensor appliance (temperature/humidity reading/alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WebGraph-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroMailAuthentication OID value, configure state conditions and alerts, and monitor any WebGraph networked thermo-hygrometer environmental sensor appliance (temperature/humidity reading/alarm status) from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5040wutCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1wtComServerCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1.2wtWebioWebGraph-8xThermometer-US-MIB
1.3.6.1.4.1.5040.1.2.9wtWebGraphThermHygroWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3wtWebGraphThermHygroConfigWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1wtWebGraphThermHygroDeviceWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.3wtWebGraphThermHygroBasicWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.3.3wtWebGraphThermHygroMailWebGraph-OLD-Thermo-Hygrometer-US-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5040.1.2.9.3.1.3.3.5wtWebGraphThermHygroMailAuthenticationWebGraph-Thermo-Hygrometer-US-MIB