WebGraph-Thermo-Hygrometer-US-MIB :: wtWebGraphThermHygroAlarmSyslogClearText

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › WebGraph-Thermo-Hygrometer-US-MIB › wtWebGraphThermHygroAlarmSyslogClearText

wtWebGraphThermHygroAlarmSyslogClearText

Module: WebGraph-Thermo-Hygrometer-US-MIB

OID (symbolic): WebGraph-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroAlarmSyslogClearText

OID (numeric): 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.30

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-write

Description: Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.

What is wtWebGraphThermHygroAlarmSyslogClearText?

The message body text sent to the syslog server when this alarm's condition clears, appended after the standard RFC 3164 priority/timestamp/host-IP header.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.30
snmpwalk -v2c -c public <target> WebGraph-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroAlarmSyslogClearText

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.30.1
snmpget -v2c -c public <target> WebGraph-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroAlarmSyslogClearText.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.30.1 s <value>

Start monitoring WebGraph networked thermo-hygrometer environmental sensor appliance (temperature/humidity reading/alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WebGraph-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroAlarmSyslogClearText OID value, configure state conditions and alerts, and monitor any WebGraph networked thermo-hygrometer environmental sensor appliance (temperature/humidity reading/alarm status) from a single console.

OID Breakdown

Upper-level ancestors (15 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5040wutCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1wtComServerCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1.2wtWebioWebGraph-8xThermometer-US-MIB
1.3.6.1.4.1.5040.1.2.9wtWebGraphThermHygroWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3wtWebGraphThermHygroConfigWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1wtWebGraphThermHygroDeviceWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.5wtWebGraphThermHygroAlarmWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.5.3wtWebGraphThermHygroAlarmTableWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1wtWebGraphThermHygroAlarmEntryWebGraph-OLD-Thermo-Hygrometer-US-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.30wtWebGraphThermHygroAlarmSyslogClearTextWebGraph-Thermo-Hygrometer-US-MIB