All MIBs › WebGraph-Thermo-Hygrometer-MIB › wtWebGraphThermHygroSnmpEnable
wtWebGraphThermHygroSnmpEnable
Module: WebGraph-Thermo-Hygrometer-MIB
OID (symbolic): WebGraph-Thermo-Hygrometer-MIB::wtWebGraphThermHygroSnmpEnable
OID (numeric): 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.5
Node type: OBJECT-TYPE
Type: OCTET STRING
Access: read-write
Description: Bit 0 schaltet SNMP frei: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : SNMP enable
What is wtWebGraphThermHygroSnmpEnable?
A 4-octet bitfield where only bit 0 of the last octet is used, and setting it enables SNMP access to the device at all. This is the master on/off switch for SNMP management, distinct from the individual community-string settings.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.5 snmpwalk -v2c -c public <target> WebGraph-Thermo-Hygrometer-MIB::wtWebGraphThermHygroSnmpEnable
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.5.1 snmpget -v2c -c public <target> WebGraph-Thermo-Hygrometer-MIB::wtWebGraphThermHygroSnmpEnable.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.5.1 s <value>
Start monitoring WebGraph thermo-hygrometer environmental sensor (temperature/humidity reading/threshold-alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WebGraph-Thermo-Hygrometer-MIB::wtWebGraphThermHygroSnmpEnable OID value, configure state conditions and alerts, and monitor any WebGraph thermo-hygrometer environmental sensor (temperature/humidity reading/threshold-alarm status) from a single console.
OID Breakdown
Upper-level ancestors (14 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.5040 | wut | Com-Server-Intern-MIB |
| 1.3.6.1.4.1.5040.1 | wtComServer | Com-Server-Intern-MIB |
| 1.3.6.1.4.1.5040.1.2 | wtWebio | WebGraph-8xThermometer-US-MIB |
| 1.3.6.1.4.1.5040.1.2.9 | wtWebGraphThermHygro | WebGraph-OLD-Thermo-Hygrometer-US-MIB |
| 1.3.6.1.4.1.5040.1.2.9.3 | wtWebGraphThermHygroConfig | WebGraph-OLD-Thermo-Hygrometer-US-MIB |
| 1.3.6.1.4.1.5040.1.2.9.3.1 | wtWebGraphThermHygroDevice | WebGraph-OLD-Thermo-Hygrometer-US-MIB |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3 | wtWebGraphThermHygroBasic | WebGraph-OLD-Thermo-Hygrometer-US-MIB |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.4 | wtWebGraphThermHygroSNMP | WebGraph-OLD-Thermo-Hygrometer-US-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.5 | wtWebGraphThermHygroSnmpEnable | WebGraph-Thermo-Hygrometer-MIB |