WebGraph-Thermo-Hygrometer-MIB :: wtWebGraphThermHygroPortSensorSelect

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › WebGraph-Thermo-Hygrometer-MIB › wtWebGraphThermHygroPortSensorSelect

wtWebGraphThermHygroPortSensorSelect

Module: WebGraph-Thermo-Hygrometer-MIB

OID (symbolic): WebGraph-Thermo-Hygrometer-MIB::wtWebGraphThermHygroPortSensorSelect

OID (numeric): 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.8

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-write

Description: Binar kodierte Optionen fur Sensor 1: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0 : PT100 Bit 1 : PT1000 (default) Bit 2-7: ungenutzt

Binar kodierte Optionen fur Sensor 2: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0 : W&T Sensor rel. Feuchte (default) Bit 1 : Skalar 0-2.5V Bit 2 : Disconnect Bit 3-7: ungenutzt

What is wtWebGraphThermHygroPortSensorSelect?

A 4-octet bitfield selecting the physical sensor element type: for sensor 1, PT100 or PT1000 (default) RTD probe; for sensor 2, the W&T relative-humidity sensor (default), a 0-2.5V analog input, or Disconnect. Admins set this to match the actual probe hardware wired into each channel.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.8
snmpwalk -v2c -c public <target> WebGraph-Thermo-Hygrometer-MIB::wtWebGraphThermHygroPortSensorSelect

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.8.1
snmpget -v2c -c public <target> WebGraph-Thermo-Hygrometer-MIB::wtWebGraphThermHygroPortSensorSelect.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.8.1 s <value>

Start monitoring WebGraph thermo-hygrometer environmental sensor (temperature/humidity reading/threshold-alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WebGraph-Thermo-Hygrometer-MIB::wtWebGraphThermHygroPortSensorSelect OID value, configure state conditions and alerts, and monitor any WebGraph thermo-hygrometer environmental sensor (temperature/humidity reading/threshold-alarm status) from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5040wutCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1wtComServerCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1.2wtWebioWebGraph-8xThermometer-US-MIB
1.3.6.1.4.1.5040.1.2.9wtWebGraphThermHygroWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3wtWebGraphThermHygroConfigWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.2wtWebGraphThermHygroPortsWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.2.1wtWebGraphThermHygroPortTableWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.2.1.1wtWebGraphThermHygroPortEntryWebGraph-OLD-Thermo-Hygrometer-US-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5040.1.2.9.3.2.1.1.8wtWebGraphThermHygroPortSensorSelectWebGraph-Thermo-Hygrometer-MIB