WebGraph-Thermo-Hygrometer-MIB :: wtWebGraphThermHygroHttpPort

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › WebGraph-Thermo-Hygrometer-MIB › wtWebGraphThermHygroHttpPort

wtWebGraphThermHygroHttpPort

Module: WebGraph-Thermo-Hygrometer-MIB

OID (symbolic): WebGraph-Thermo-Hygrometer-MIB::wtWebGraphThermHygroHttpPort

OID (numeric): 1.3.6.1.4.1.5040.1.2.9.3.1.3.2.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: HTTP Port, an den die TCP-Anfragen gesendet werden konnen (Default: 80).

What is wtWebGraphThermHygroHttpPort?

Sets the TCP port the device's built-in web server listens on for HTTP requests, defaulting to 80. Admins change this if port 80 is already used by something else on the network, or as a minor security measure.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.3.2.3
snmpwalk -v2c -c public <target> WebGraph-Thermo-Hygrometer-MIB::wtWebGraphThermHygroHttpPort

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.3.2.3.1
snmpget -v2c -c public <target> WebGraph-Thermo-Hygrometer-MIB::wtWebGraphThermHygroHttpPort.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5040.1.2.9.3.1.3.2.3.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> wtWebGraphThermHygroHttpPort.1

Start monitoring WebGraph thermo-hygrometer environmental sensor (temperature/humidity reading/threshold-alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WebGraph-Thermo-Hygrometer-MIB::wtWebGraphThermHygroHttpPort OID value, configure state conditions and alerts, and monitor any WebGraph thermo-hygrometer environmental sensor (temperature/humidity reading/threshold-alarm status) from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5040wutCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1wtComServerCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1.2wtWebioWebGraph-8xThermometer-US-MIB
1.3.6.1.4.1.5040.1.2.9wtWebGraphThermHygroWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3wtWebGraphThermHygroConfigWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1wtWebGraphThermHygroDeviceWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.3wtWebGraphThermHygroBasicWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.3.2wtWebGraphThermHygroHTTPWebGraph-OLD-Thermo-Hygrometer-US-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5040.1.2.9.3.1.3.2.3wtWebGraphThermHygroHttpPortWebGraph-Thermo-Hygrometer-MIB