All MIBs › WebGraph-Thermo-Hygrometer-MIB › wtWebGraphThermHygroAlarmSyslogPort
wtWebGraphThermHygroAlarmSyslogPort
Module: WebGraph-Thermo-Hygrometer-MIB
OID (symbolic): WebGraph-Thermo-Hygrometer-MIB::wtWebGraphThermHygroAlarmSyslogPort
OID (numeric): 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.28
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Portnummer des Gerates, dass eine Syslog-Nachricht empfangen soll, default Port ist 514.
What is wtWebGraphThermHygroAlarmSyslogPort?
The UDP port number of the device that should receive this alarm's syslog message, defaulting to the standard syslog port 514.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.28 snmpwalk -v2c -c public <target> WebGraph-Thermo-Hygrometer-MIB::wtWebGraphThermHygroAlarmSyslogPort
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.28.1 snmpget -v2c -c public <target> WebGraph-Thermo-Hygrometer-MIB::wtWebGraphThermHygroAlarmSyslogPort.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.28.1 i <value>
Start monitoring WebGraph thermo-hygrometer environmental sensor (temperature/humidity reading/threshold-alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WebGraph-Thermo-Hygrometer-MIB::wtWebGraphThermHygroAlarmSyslogPort OID value, configure state conditions and alerts, and monitor any WebGraph thermo-hygrometer environmental sensor (temperature/humidity reading/threshold-alarm status) from a single console.
OID Breakdown
Upper-level ancestors (15 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.5040 | wut | Com-Server-Intern-MIB |
| 1.3.6.1.4.1.5040.1 | wtComServer | Com-Server-Intern-MIB |
| 1.3.6.1.4.1.5040.1.2 | wtWebio | WebGraph-8xThermometer-US-MIB |
| 1.3.6.1.4.1.5040.1.2.9 | wtWebGraphThermHygro | WebGraph-OLD-Thermo-Hygrometer-US-MIB |
| 1.3.6.1.4.1.5040.1.2.9.3 | wtWebGraphThermHygroConfig | WebGraph-OLD-Thermo-Hygrometer-US-MIB |
| 1.3.6.1.4.1.5040.1.2.9.3.1 | wtWebGraphThermHygroDevice | WebGraph-OLD-Thermo-Hygrometer-US-MIB |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5 | wtWebGraphThermHygroAlarm | WebGraph-OLD-Thermo-Hygrometer-US-MIB |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3 | wtWebGraphThermHygroAlarmTable | WebGraph-OLD-Thermo-Hygrometer-US-MIB |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1 | wtWebGraphThermHygroAlarmEntry | WebGraph-OLD-Thermo-Hygrometer-US-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.28 | wtWebGraphThermHygroAlarmSyslogPort | WebGraph-Thermo-Hygrometer-MIB |