WebGraph-Thermo-Hygrometer-MIB :: wtWebGraphThermHygroAlarmSyslogClearText

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › WebGraph-Thermo-Hygrometer-MIB › wtWebGraphThermHygroAlarmSyslogClearText

wtWebGraphThermHygroAlarmSyslogClearText

Module: WebGraph-Thermo-Hygrometer-MIB

OID (symbolic): WebGraph-Thermo-Hygrometer-MIB::wtWebGraphThermHygroAlarmSyslogClearText

OID (numeric): 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.30

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-write

Description: Jede Syslog-Nachricht beginnt mit einem Prioritatsschlussel, einem Zeitstempel und der Host Ip-Nummer gemass RFC3164. Dieser Text wird im darauf folgenden Syslog-Nachrichtenteil gesendet.

What is wtWebGraphThermHygroAlarmSyslogClearText?

The custom text sent as the message body of the syslog entry generated when this alarm condition clears, appended after the standard RFC 3164 priority tag, timestamp, and host IP.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.30
snmpwalk -v2c -c public <target> WebGraph-Thermo-Hygrometer-MIB::wtWebGraphThermHygroAlarmSyslogClearText

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.30.1
snmpget -v2c -c public <target> WebGraph-Thermo-Hygrometer-MIB::wtWebGraphThermHygroAlarmSyslogClearText.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.30.1 s <value>

Start monitoring WebGraph thermo-hygrometer environmental sensor (temperature/humidity reading/threshold-alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WebGraph-Thermo-Hygrometer-MIB::wtWebGraphThermHygroAlarmSyslogClearText OID value, configure state conditions and alerts, and monitor any WebGraph thermo-hygrometer environmental sensor (temperature/humidity reading/threshold-alarm status) from a single console.

OID Breakdown

Upper-level ancestors (15 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5040wutCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1wtComServerCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1.2wtWebioWebGraph-8xThermometer-US-MIB
1.3.6.1.4.1.5040.1.2.9wtWebGraphThermHygroWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3wtWebGraphThermHygroConfigWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1wtWebGraphThermHygroDeviceWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.5wtWebGraphThermHygroAlarmWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.5.3wtWebGraphThermHygroAlarmTableWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1wtWebGraphThermHygroAlarmEntryWebGraph-OLD-Thermo-Hygrometer-US-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.30wtWebGraphThermHygroAlarmSyslogClearTextWebGraph-Thermo-Hygrometer-MIB