WebGraph-Thermo-Hygrometer-MIB :: wtWebGraphThermHygroAlarmEMailAddr

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › WebGraph-Thermo-Hygrometer-MIB › wtWebGraphThermHygroAlarmEMailAddr

wtWebGraphThermHygroAlarmEMailAddr

Module: WebGraph-Thermo-Hygrometer-MIB

OID (symbolic): WebGraph-Thermo-Hygrometer-MIB::wtWebGraphThermHygroAlarmEMailAddr

OID (numeric): 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.8

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-write

Description: E-Mail Adresse, an die die Alarmmail gesendet werden soll.

What is wtWebGraphThermHygroAlarmEMailAddr?

The email address this alarm's notification is sent to when the email notification channel is enabled.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.8
snmpwalk -v2c -c public <target> WebGraph-Thermo-Hygrometer-MIB::wtWebGraphThermHygroAlarmEMailAddr

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.8.1
snmpget -v2c -c public <target> WebGraph-Thermo-Hygrometer-MIB::wtWebGraphThermHygroAlarmEMailAddr.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.8.1 s <value>

Start monitoring WebGraph thermo-hygrometer environmental sensor (temperature/humidity reading/threshold-alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WebGraph-Thermo-Hygrometer-MIB::wtWebGraphThermHygroAlarmEMailAddr OID value, configure state conditions and alerts, and monitor any WebGraph thermo-hygrometer environmental sensor (temperature/humidity reading/threshold-alarm status) from a single console.

OID Breakdown

Upper-level ancestors (15 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5040wutCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1wtComServerCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1.2wtWebioWebGraph-8xThermometer-US-MIB
1.3.6.1.4.1.5040.1.2.9wtWebGraphThermHygroWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3wtWebGraphThermHygroConfigWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1wtWebGraphThermHygroDeviceWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.5wtWebGraphThermHygroAlarmWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.5.3wtWebGraphThermHygroAlarmTableWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1wtWebGraphThermHygroAlarmEntryWebGraph-OLD-Thermo-Hygrometer-US-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.8wtWebGraphThermHygroAlarmEMailAddrWebGraph-Thermo-Hygrometer-MIB