WebGraph-Thermo-Hygro-Barometer-US-MIB :: wtWebGraphThermoBaroStTzStopMonth

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › WebGraph-Thermo-Hygro-Barometer-US-MIB › wtWebGraphThermoBaroStTzStopMonth

wtWebGraphThermoBaroStTzStopMonth

Module: WebGraph-Thermo-Hygro-Barometer-US-MIB

OID (symbolic): WebGraph-Thermo-Hygro-Barometer-US-MIB::wtWebGraphThermoBaroStTzStopMonth

OID (numeric): 1.3.6.1.4.1.5040.1.2.37.3.1.2.1.12

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Month in which the change is made from summer time to winter time.

What is wtWebGraphThermoBaroStTzStopMonth?

Selects the calendar month in which the device switches back from summer (daylight saving) time to winter time.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.37.3.1.2.1.12
snmpwalk -v2c -c public <target> WebGraph-Thermo-Hygro-Barometer-US-MIB::wtWebGraphThermoBaroStTzStopMonth

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.37.3.1.2.1.12.1
snmpget -v2c -c public <target> WebGraph-Thermo-Hygro-Barometer-US-MIB::wtWebGraphThermoBaroStTzStopMonth.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5040.1.2.37.3.1.2.1.12.1 i <value>

Start monitoring WebGraph environmental monitoring sensor, temperature/humidity/barometric pressure (per-sensor reading/alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WebGraph-Thermo-Hygro-Barometer-US-MIB::wtWebGraphThermoBaroStTzStopMonth OID value, configure state conditions and alerts, and monitor any WebGraph environmental monitoring sensor, temperature/humidity/barometric pressure (per-sensor reading/alarm status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5040wutCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1wtComServerCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1.2wtWebioWebGraph-8xThermometer-US-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5040.1.2.37wtWebGraphThermoBaroWebGraph-Thermo-Hygro-Barometer-US-MIB
1.3.6.1.4.1.5040.1.2.37.3wtWebGraphThermoBaroConfigWebGraph-Thermo-Hygro-Barometer-US-MIB
1.3.6.1.4.1.5040.1.2.37.3.1wtWebGraphThermoBaroDeviceWebGraph-Thermo-Hygro-Barometer-US-MIB
1.3.6.1.4.1.5040.1.2.37.3.1.2wtWebGraphThermoBaroTimeDateWebGraph-Thermo-Hygro-Barometer-US-MIB
1.3.6.1.4.1.5040.1.2.37.3.1.2.1wtWebGraphThermoBaroTimeZoneWebGraph-Thermo-Hygro-Barometer-US-MIB
1.3.6.1.4.1.5040.1.2.37.3.1.2.1.12wtWebGraphThermoBaroStTzStopMonthWebGraph-Thermo-Hygro-Barometer-US-MIB