WebGraph-Thermo-Hygro-Barometer-US-MIB :: wtWebGraphThermoBaroStTzStopMin

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › WebGraph-Thermo-Hygro-Barometer-US-MIB › wtWebGraphThermoBaroStTzStopMin

wtWebGraphThermoBaroStTzStopMin

Module: WebGraph-Thermo-Hygro-Barometer-US-MIB

OID (symbolic): WebGraph-Thermo-Hygro-Barometer-US-MIB::wtWebGraphThermoBaroStTzStopMin

OID (numeric): 1.3.6.1.4.1.5040.1.2.37.3.1.2.1.16

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Minute at which the time zone is changed from summer to winter time with respect to UTC.

What is wtWebGraphThermoBaroStTzStopMin?

Sets the minute, in UTC, at which the switch from summer back to winter time takes effect, paired with wtWebGraphThermoBaroStTzStopHrs.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.37.3.1.2.1.16
snmpwalk -v2c -c public <target> WebGraph-Thermo-Hygro-Barometer-US-MIB::wtWebGraphThermoBaroStTzStopMin

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.37.3.1.2.1.16.1
snmpget -v2c -c public <target> WebGraph-Thermo-Hygro-Barometer-US-MIB::wtWebGraphThermoBaroStTzStopMin.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5040.1.2.37.3.1.2.1.16.1 i <value>

Start monitoring WebGraph environmental monitoring sensor, temperature/humidity/barometric pressure (per-sensor reading/alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WebGraph-Thermo-Hygro-Barometer-US-MIB::wtWebGraphThermoBaroStTzStopMin OID value, configure state conditions and alerts, and monitor any WebGraph environmental monitoring sensor, temperature/humidity/barometric pressure (per-sensor reading/alarm status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5040wutCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1wtComServerCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1.2wtWebioWebGraph-8xThermometer-US-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5040.1.2.37wtWebGraphThermoBaroWebGraph-Thermo-Hygro-Barometer-US-MIB
1.3.6.1.4.1.5040.1.2.37.3wtWebGraphThermoBaroConfigWebGraph-Thermo-Hygro-Barometer-US-MIB
1.3.6.1.4.1.5040.1.2.37.3.1wtWebGraphThermoBaroDeviceWebGraph-Thermo-Hygro-Barometer-US-MIB
1.3.6.1.4.1.5040.1.2.37.3.1.2wtWebGraphThermoBaroTimeDateWebGraph-Thermo-Hygro-Barometer-US-MIB
1.3.6.1.4.1.5040.1.2.37.3.1.2.1wtWebGraphThermoBaroTimeZoneWebGraph-Thermo-Hygro-Barometer-US-MIB
1.3.6.1.4.1.5040.1.2.37.3.1.2.1.16wtWebGraphThermoBaroStTzStopMinWebGraph-Thermo-Hygro-Barometer-US-MIB