WebGraph-Thermo-Hygro-Barometer-US-MIB :: wtWebGraphThermoBaroIpAddress

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › WebGraph-Thermo-Hygro-Barometer-US-MIB › wtWebGraphThermoBaroIpAddress

wtWebGraphThermoBaroIpAddress

Module: WebGraph-Thermo-Hygro-Barometer-US-MIB

OID (symbolic): WebGraph-Thermo-Hygro-Barometer-US-MIB::wtWebGraphThermoBaroIpAddress

OID (numeric): 1.3.6.1.4.1.5040.1.2.37.3.1.3.1.1

Node type: OBJECT-TYPE

Type: IpAddress

Access: read-write

Description: IP address of the Webio

What is wtWebGraphThermoBaroIpAddress?

Holds the IPv4 address assigned to the Webio unit's network interface, configurable by an admin for static addressing.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.37.3.1.3.1.1
snmpwalk -v2c -c public <target> WebGraph-Thermo-Hygro-Barometer-US-MIB::wtWebGraphThermoBaroIpAddress

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.37.3.1.3.1.1.1
snmpget -v2c -c public <target> WebGraph-Thermo-Hygro-Barometer-US-MIB::wtWebGraphThermoBaroIpAddress.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5040.1.2.37.3.1.3.1.1.1 a <value>

Start monitoring WebGraph environmental monitoring sensor, temperature/humidity/barometric pressure (per-sensor reading/alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WebGraph-Thermo-Hygro-Barometer-US-MIB::wtWebGraphThermoBaroIpAddress OID value, configure state conditions and alerts, and monitor any WebGraph environmental monitoring sensor, temperature/humidity/barometric pressure (per-sensor reading/alarm status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5040wutCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1wtComServerCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1.2wtWebioWebGraph-8xThermometer-US-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5040.1.2.37wtWebGraphThermoBaroWebGraph-Thermo-Hygro-Barometer-US-MIB
1.3.6.1.4.1.5040.1.2.37.3wtWebGraphThermoBaroConfigWebGraph-Thermo-Hygro-Barometer-US-MIB
1.3.6.1.4.1.5040.1.2.37.3.1wtWebGraphThermoBaroDeviceWebGraph-Thermo-Hygro-Barometer-US-MIB
1.3.6.1.4.1.5040.1.2.37.3.1.3wtWebGraphThermoBaroBasicWebGraph-Thermo-Hygro-Barometer-US-MIB
1.3.6.1.4.1.5040.1.2.37.3.1.3.1wtWebGraphThermoBaroNetworkWebGraph-Thermo-Hygro-Barometer-US-MIB
1.3.6.1.4.1.5040.1.2.37.3.1.3.1.1wtWebGraphThermoBaroIpAddressWebGraph-Thermo-Hygro-Barometer-US-MIB