wtWebGraphThermoBaroDiagErrorIndex

Module: WebGraph-Thermo-Hygro-Barometer-US-MIB

OID (symbolic): WebGraph-Thermo-Hygro-Barometer-US-MIB::wtWebGraphThermoBaroDiagErrorIndex

OID (numeric): 1.3.6.1.4.1.5040.1.2.37.4.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The value of this variable is used as an index to read an error massege from wtWebGraphThermoBaroDiagErrorMessage. Errors are numbered from 1 to wtWebGraphThermoBaroDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebGraphThermoBaroDiagErrorMessage.

What is wtWebGraphThermoBaroDiagErrorIndex?

Selects which logged error entry (numbered 1 through wtWebGraphThermoBaroDiagErrorCount) to read next. An admin writes an index here, then reads wtWebGraphThermoBaroDiagErrorMessage to retrieve that specific error's text.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.37.4.3
snmpwalk -v2c -c public <target> WebGraph-Thermo-Hygro-Barometer-US-MIB::wtWebGraphThermoBaroDiagErrorIndex

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.37.4.3.1
snmpget -v2c -c public <target> WebGraph-Thermo-Hygro-Barometer-US-MIB::wtWebGraphThermoBaroDiagErrorIndex.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5040.1.2.37.4.3.1 i <value>

Start monitoring WebGraph environmental monitoring sensor, temperature/humidity/barometric pressure (per-sensor reading/alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WebGraph-Thermo-Hygro-Barometer-US-MIB::wtWebGraphThermoBaroDiagErrorIndex OID value, configure state conditions and alerts, and monitor any WebGraph environmental monitoring sensor, temperature/humidity/barometric pressure (per-sensor reading/alarm status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5040wutCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1wtComServerCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1.2wtWebioWebGraph-8xThermometer-US-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5040.1.2.37wtWebGraphThermoBaroWebGraph-Thermo-Hygro-Barometer-US-MIB
1.3.6.1.4.1.5040.1.2.37.4wtWebGraphThermoBaroDiagWebGraph-Thermo-Hygro-Barometer-US-MIB
1.3.6.1.4.1.5040.1.2.37.4.3wtWebGraphThermoBaroDiagErrorIndexWebGraph-Thermo-Hygro-Barometer-US-MIB