WebGraph-OLD-Thermo-Hygrometer-US-MIB :: wtWebGraphThermHygroUdpPort

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › WebGraph-OLD-Thermo-Hygrometer-US-MIB › wtWebGraphThermHygroUdpPort

wtWebGraphThermHygroUdpPort

Module: WebGraph-OLD-Thermo-Hygrometer-US-MIB

OID (symbolic): WebGraph-OLD-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroUdpPort

OID (numeric): 1.3.6.1.4.1.5040.1.2.9.3.1.3.5.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device.

What is wtWebGraphThermHygroUdpPort?

The UDP port on which the device listens for short-form GET queries -- a lightweight, non-SNMP polling protocol WuT devices support for quick value reads. Must be unique on the device and match whatever the polling client is configured to use.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.3.5.1
snmpwalk -v2c -c public <target> WebGraph-OLD-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroUdpPort

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.3.5.1.1
snmpget -v2c -c public <target> WebGraph-OLD-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroUdpPort.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5040.1.2.9.3.1.3.5.1.1 i <value>

Start monitoring Wiesemann & Theis networked environmental sensors with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WebGraph-OLD-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroUdpPort OID value, configure state conditions and alerts, and monitor any Wiesemann & Theis networked environmental sensors from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5040wutCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1wtComServerCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1.2wtWebioWebGraph-8xThermometer-US-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5040.1.2.9wtWebGraphThermHygroWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3wtWebGraphThermHygroConfigWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1wtWebGraphThermHygroDeviceWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.3wtWebGraphThermHygroBasicWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.3.5wtWebGraphThermHygroUDPWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.3.5.1wtWebGraphThermHygroUdpPortWebGraph-OLD-Thermo-Hygrometer-US-MIB