All MIBs › WebGraph-OLD-Thermo-Hygrometer-US-MIB › wtWebGraphThermHygroTsEnable
wtWebGraphThermHygroTsEnable
Module: WebGraph-OLD-Thermo-Hygrometer-US-MIB
OID (symbolic): WebGraph-OLD-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroTsEnable
OID (numeric): 1.3.6.1.4.1.5040.1.2.9.3.1.2.2.3
Node type: OBJECT-TYPE
Type: OCTET STRING
Access: read-write
Description: Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server
What is wtWebGraphThermHygroTsEnable?
A bit-coded flag (bit 0 of the 4th octet) that turns on time-server synchronization. When disabled, the device relies solely on its own internal clock, which can drift over long uptimes.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.2.2.3 snmpwalk -v2c -c public <target> WebGraph-OLD-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroTsEnable
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.2.2.3.1 snmpget -v2c -c public <target> WebGraph-OLD-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroTsEnable.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.5040.1.2.9.3.1.2.2.3.1 s <value>
Start monitoring Wiesemann & Theis networked environmental sensors with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WebGraph-OLD-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroTsEnable OID value, configure state conditions and alerts, and monitor any Wiesemann & Theis networked environmental sensors from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.5040 | wut | Com-Server-Intern-MIB |
| 1.3.6.1.4.1.5040.1 | wtComServer | Com-Server-Intern-MIB |
| 1.3.6.1.4.1.5040.1.2 | wtWebio | WebGraph-8xThermometer-US-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.5040.1.2.9 | wtWebGraphThermHygro | WebGraph-OLD-Thermo-Hygrometer-US-MIB |
| 1.3.6.1.4.1.5040.1.2.9.3 | wtWebGraphThermHygroConfig | WebGraph-OLD-Thermo-Hygrometer-US-MIB |
| 1.3.6.1.4.1.5040.1.2.9.3.1 | wtWebGraphThermHygroDevice | WebGraph-OLD-Thermo-Hygrometer-US-MIB |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2 | wtWebGraphThermHygroTimeDate | WebGraph-OLD-Thermo-Hygrometer-US-MIB |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.2 | wtWebGraphThermHygroTimeServer | WebGraph-OLD-Thermo-Hygrometer-US-MIB |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.2.3 | wtWebGraphThermHygroTsEnable | WebGraph-OLD-Thermo-Hygrometer-US-MIB |