OID (numeric): 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.2

Node type: OBJECT-TYPE

Type: IpAddress

Access: read-write

Description: Subnet mask of the Webio

What is wtWebGraphThermHygroSubnetMask?

The IPv4 subnet mask configured on the device. Must match the actual local network's mask or the device won't be able to communicate correctly with other hosts on its segment.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.2
snmpwalk -v2c -c public <target> WebGraph-OLD-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroSubnetMask

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.2.1
snmpget -v2c -c public <target> WebGraph-OLD-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroSubnetMask.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.2.1 a <value>

Start monitoring Wiesemann & Theis networked environmental sensors with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WebGraph-OLD-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroSubnetMask OID value, configure state conditions and alerts, and monitor any Wiesemann & Theis networked environmental sensors from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5040wutCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1wtComServerCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1.2wtWebioWebGraph-8xThermometer-US-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5040.1.2.9wtWebGraphThermHygroWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3wtWebGraphThermHygroConfigWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1wtWebGraphThermHygroDeviceWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.3wtWebGraphThermHygroBasicWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.3.1wtWebGraphThermHygroNetworkWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.3.1.2wtWebGraphThermHygroSubnetMaskWebGraph-OLD-Thermo-Hygrometer-US-MIB