All MIBs › WebGraph-OLD-Thermo-Hygrometer-US-MIB › wtWebGraphThermHygroSessCntrlConfigPassword
wtWebGraphThermHygroSessCntrlConfigPassword
Module: WebGraph-OLD-Thermo-Hygrometer-US-MIB
OID (symbolic): WebGraph-OLD-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroSessCntrlConfigPassword
OID (numeric): 1.3.6.1.4.1.5040.1.2.9.2.5
Node type: OBJECT-TYPE
Type: OCTET STRING
Access: read-write
Description: This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer.
What is wtWebGraphThermHygroSessCntrlConfigPassword?
The configurator-level password gating write access to configurator variables; it can be changed by either the admin or the configurator, and defaults to 'public' if unset. Reading it back always yields a null value, so the password can't be retrieved via SNMP.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.2.5 snmpwalk -v2c -c public <target> WebGraph-OLD-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroSessCntrlConfigPassword
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.2.5.1 snmpget -v2c -c public <target> WebGraph-OLD-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroSessCntrlConfigPassword.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.5040.1.2.9.2.5.1 s <value>
Start monitoring Wiesemann & Theis networked environmental sensors with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WebGraph-OLD-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroSessCntrlConfigPassword OID value, configure state conditions and alerts, and monitor any Wiesemann & Theis networked environmental sensors from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.5040 | wut | Com-Server-Intern-MIB |
| 1.3.6.1.4.1.5040.1 | wtComServer | Com-Server-Intern-MIB |
| 1.3.6.1.4.1.5040.1.2 | wtWebio | WebGraph-8xThermometer-US-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.5040.1.2.9 | wtWebGraphThermHygro | WebGraph-OLD-Thermo-Hygrometer-US-MIB |
| 1.3.6.1.4.1.5040.1.2.9.2 | wtWebGraphThermHygroSessCntrl | WebGraph-OLD-Thermo-Hygrometer-US-MIB |
| 1.3.6.1.4.1.5040.1.2.9.2.5 | wtWebGraphThermHygroSessCntrlConfigPassword | WebGraph-OLD-Thermo-Hygrometer-US-MIB |