WebGraph-OLD-Thermo-Hygrometer-US-MIB :: wtWebGraphThermHygroFTPServerControlPort

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › WebGraph-OLD-Thermo-Hygrometer-US-MIB › wtWebGraphThermHygroFTPServerControlPort

wtWebGraphThermHygroFTPServerControlPort

Module: WebGraph-OLD-Thermo-Hygrometer-US-MIB

OID (symbolic): WebGraph-OLD-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroFTPServerControlPort

OID (numeric): 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Portnumber of the control port of the FTP server, default 21.

What is wtWebGraphThermHygroFTPServerControlPort?

The TCP control port of the FTP server, defaulting to the standard port 21. Change this only if the target FTP server uses a nonstandard control-channel port.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.2
snmpwalk -v2c -c public <target> WebGraph-OLD-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroFTPServerControlPort

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.2.1
snmpget -v2c -c public <target> WebGraph-OLD-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroFTPServerControlPort.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.2.1 i <value>

Start monitoring Wiesemann & Theis networked environmental sensors with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WebGraph-OLD-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroFTPServerControlPort OID value, configure state conditions and alerts, and monitor any Wiesemann & Theis networked environmental sensors from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5040wutCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1wtComServerCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1.2wtWebioWebGraph-8xThermometer-US-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5040.1.2.9wtWebGraphThermHygroWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3wtWebGraphThermHygroConfigWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1wtWebGraphThermHygroDeviceWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.3wtWebGraphThermHygroBasicWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.3.7wtWebGraphThermHygroFTPWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.3.7.2wtWebGraphThermHygroFTPServerControlPortWebGraph-OLD-Thermo-Hygrometer-US-MIB