WebGraph-OLD-Thermo-Hygrometer-US-MIB :: wtWebGraphThermHygroAlarmTcpPort

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › WebGraph-OLD-Thermo-Hygrometer-US-MIB › wtWebGraphThermHygroAlarmTcpPort

wtWebGraphThermHygroAlarmTcpPort

Module: WebGraph-OLD-Thermo-Hygrometer-US-MIB

OID (symbolic): WebGraph-OLD-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroAlarmTcpPort

OID (numeric): 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.15

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Port number of the TCP server which accepts the trap.

What is wtWebGraphThermHygroAlarmTcpPort?

The TCP port number of the server that receives this alarm's TCP notification. Must match the port the receiving application is actually listening on.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.15
snmpwalk -v2c -c public <target> WebGraph-OLD-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroAlarmTcpPort

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.15.1
snmpget -v2c -c public <target> WebGraph-OLD-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroAlarmTcpPort.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.15.1 i <value>

Start monitoring Wiesemann & Theis networked environmental sensors with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WebGraph-OLD-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroAlarmTcpPort OID value, configure state conditions and alerts, and monitor any Wiesemann & Theis networked environmental sensors from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5040wutCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1wtComServerCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1.2wtWebioWebGraph-8xThermometer-US-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5040.1.2.9wtWebGraphThermHygroWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3wtWebGraphThermHygroConfigWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1wtWebGraphThermHygroDeviceWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.5wtWebGraphThermHygroAlarmWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.5.3wtWebGraphThermHygroAlarmTableWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1wtWebGraphThermHygroAlarmEntryWebGraph-OLD-Thermo-Hygrometer-US-MIB
1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.15wtWebGraphThermHygroAlarmTcpPortWebGraph-OLD-Thermo-Hygrometer-US-MIB