All MIBs › WebGraph-OLD-Thermo-Hygrometer-US-MIB › wtWebGraphThermHygroAlarmSyslogPort
wtWebGraphThermHygroAlarmSyslogPort
Module: WebGraph-OLD-Thermo-Hygrometer-US-MIB
OID (symbolic): WebGraph-OLD-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroAlarmSyslogPort
OID (numeric): 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.28
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Port number of the syslog server to which the Webio device should send syslog messages.
What is wtWebGraphThermHygroAlarmSyslogPort?
The UDP port number of the syslog server this alarm slot sends messages to. Must match the port the target syslog collector is listening on.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.28 snmpwalk -v2c -c public <target> WebGraph-OLD-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroAlarmSyslogPort
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.28.1 snmpget -v2c -c public <target> WebGraph-OLD-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroAlarmSyslogPort.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.28.1 i <value>
Start monitoring Wiesemann & Theis networked environmental sensors with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WebGraph-OLD-Thermo-Hygrometer-US-MIB::wtWebGraphThermHygroAlarmSyslogPort OID value, configure state conditions and alerts, and monitor any Wiesemann & Theis networked environmental sensors from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.5040 | wut | Com-Server-Intern-MIB |
| 1.3.6.1.4.1.5040.1 | wtComServer | Com-Server-Intern-MIB |
| 1.3.6.1.4.1.5040.1.2 | wtWebio | WebGraph-8xThermometer-US-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.5040.1.2.9 | wtWebGraphThermHygro | WebGraph-OLD-Thermo-Hygrometer-US-MIB |
| 1.3.6.1.4.1.5040.1.2.9.3 | wtWebGraphThermHygroConfig | WebGraph-OLD-Thermo-Hygrometer-US-MIB |
| 1.3.6.1.4.1.5040.1.2.9.3.1 | wtWebGraphThermHygroDevice | WebGraph-OLD-Thermo-Hygrometer-US-MIB |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5 | wtWebGraphThermHygroAlarm | WebGraph-OLD-Thermo-Hygrometer-US-MIB |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3 | wtWebGraphThermHygroAlarmTable | WebGraph-OLD-Thermo-Hygrometer-US-MIB |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1 | wtWebGraphThermHygroAlarmEntry | WebGraph-OLD-Thermo-Hygrometer-US-MIB |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.28 | wtWebGraphThermHygroAlarmSyslogPort | WebGraph-OLD-Thermo-Hygrometer-US-MIB |