All MIBs › WebGraph-AnalogIn-57644-US-MIB › wtWebGraphAnalogIn57644AlarmClearMailSubject
wtWebGraphAnalogIn57644AlarmClearMailSubject
Module: WebGraph-AnalogIn-57644-US-MIB
OID (symbolic): WebGraph-AnalogIn-57644-US-MIB::wtWebGraphAnalogIn57644AlarmClearMailSubject
OID (numeric): 1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.17
Node type: OBJECT-TYPE
Type: OCTET STRING
Access: read-write
Description: Subject line for alarm clear mail.
What is wtWebGraphAnalogIn57644AlarmClearMailSubject?
This is the subject line used for the email notification sent when this alarm's condition clears (returns to normal), as distinct from wtWebGraphAnalogIn57644AlarmMailSubject which is used when the alarm first fires.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.17 snmpwalk -v2c -c public <target> WebGraph-AnalogIn-57644-US-MIB::wtWebGraphAnalogIn57644AlarmClearMailSubject
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.17.1 snmpget -v2c -c public <target> WebGraph-AnalogIn-57644-US-MIB::wtWebGraphAnalogIn57644AlarmClearMailSubject.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.17.1 s <value>
Start monitoring WebGraph/WebTech model 57644 analog input environmental monitoring unit (per-channel reading/binary-alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WebGraph-AnalogIn-57644-US-MIB::wtWebGraphAnalogIn57644AlarmClearMailSubject OID value, configure state conditions and alerts, and monitor any WebGraph/WebTech model 57644 analog input environmental monitoring unit (per-channel reading/binary-alarm status) from a single console.
OID Breakdown
Upper-level ancestors (15 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.5040 | wut | Com-Server-Intern-MIB |
| 1.3.6.1.4.1.5040.1 | wtComServer | Com-Server-Intern-MIB |
| 1.3.6.1.4.1.5040.1.2 | wtWebio | WebGraph-8xThermometer-US-MIB |
| 1.3.6.1.4.1.5040.1.2.12 | wtWebGraphAnalogIn57643 | WebGraph-AnalogIn-57643-US-MIB |
| 1.3.6.1.4.1.5040.1.2.12.3 | wtWebGraphAnalogIn57643Config | WebGraph-AnalogIn-57643-US-MIB |
| 1.3.6.1.4.1.5040.1.2.12.3.1 | wtWebGraphAnalogIn57643Device | WebGraph-AnalogIn-57643-US-MIB |
| 1.3.6.1.4.1.5040.1.2.12.3.1.5 | wtWebGraphAnalogIn57643Alarm | WebGraph-AnalogIn-57643-US-MIB |
| 1.3.6.1.4.1.5040.1.2.12.3.1.5.3 | wtWebGraphAnalogIn57643AlarmTable | WebGraph-AnalogIn-57643-US-MIB |
| 1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1 | wtWebGraphAnalogIn57643AlarmEntry | WebGraph-AnalogIn-57643-US-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.17 | wtWebGraphAnalogIn57644AlarmClearMailSubject | WebGraph-AnalogIn-57644-US-MIB |