Description: Hysterese rel. Humidity in percent with maximum 2 decimal places.
What is wtWebGraphAnalogIn57644Alarm2Hysteresis?
This sets the hysteresis margin, in percent relative humidity (up to 2 decimal places), that a humidity reading must move back past wtWebGraphAnalogIn57644Alarm2Max/Min by before this second threshold clears, mirroring the role of wtWebGraphAnalogIn57644AlarmHysteresis but for the humidity limits.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.23 snmpwalk -v2c -c public <target> WebGraph-AnalogIn-57644-US-MIB::wtWebGraphAnalogIn57644Alarm2Hysteresis
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.23.1 snmpget -v2c -c public <target> WebGraph-AnalogIn-57644-US-MIB::wtWebGraphAnalogIn57644Alarm2Hysteresis.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.23.1 s <value>
Start monitoring WebGraph/WebTech model 57644 analog input environmental monitoring unit (per-channel reading/binary-alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WebGraph-AnalogIn-57644-US-MIB::wtWebGraphAnalogIn57644Alarm2Hysteresis OID value, configure state conditions and alerts, and monitor any WebGraph/WebTech model 57644 analog input environmental monitoring unit (per-channel reading/binary-alarm status) from a single console.
OID Breakdown
Upper-level ancestors (15 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.5040 | wut | Com-Server-Intern-MIB |
| 1.3.6.1.4.1.5040.1 | wtComServer | Com-Server-Intern-MIB |
| 1.3.6.1.4.1.5040.1.2 | wtWebio | WebGraph-8xThermometer-US-MIB |
| 1.3.6.1.4.1.5040.1.2.12 | wtWebGraphAnalogIn57643 | WebGraph-AnalogIn-57643-US-MIB |
| 1.3.6.1.4.1.5040.1.2.12.3 | wtWebGraphAnalogIn57643Config | WebGraph-AnalogIn-57643-US-MIB |
| 1.3.6.1.4.1.5040.1.2.12.3.1 | wtWebGraphAnalogIn57643Device | WebGraph-AnalogIn-57643-US-MIB |
| 1.3.6.1.4.1.5040.1.2.12.3.1.5 | wtWebGraphAnalogIn57643Alarm | WebGraph-AnalogIn-57643-US-MIB |
| 1.3.6.1.4.1.5040.1.2.12.3.1.5.3 | wtWebGraphAnalogIn57643AlarmTable | WebGraph-AnalogIn-57643-US-MIB |
| 1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1 | wtWebGraphAnalogIn57643AlarmEntry | WebGraph-AnalogIn-57643-US-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.23 | wtWebGraphAnalogIn57644Alarm2Hysteresis | WebGraph-AnalogIn-57644-US-MIB |