All MIBs › WebGraph-AnalogIO-57661-US-MIB › wtWebGraphAnalog57661ReportEMailAddr
wtWebGraphAnalog57661ReportEMailAddr
Module: WebGraph-AnalogIO-57661-US-MIB
OID (symbolic): WebGraph-AnalogIO-57661-US-MIB::wtWebGraphAnalog57661ReportEMailAddr
OID (numeric): 1.3.6.1.4.1.5040.1.2.28.3.1.7.3.1.8
Node type: OBJECT-TYPE
Type: OCTET STRING
Access: read-write
Description: E-Mail address for sending the alarm mail to.
What is wtWebGraphAnalog57661ReportEMailAddr?
The email address this report is sent to when the mail channel is enabled in wtWebGraphAnalog57661ReportMethodeEnable. The source MIB's description literally says 'alarm mail,' apparently copy-pasted from the identical field in the sibling Alarm group, but its OID position under the Report table means it functions as this report's own recipient address.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.28.3.1.7.3.1.8 snmpwalk -v2c -c public <target> WebGraph-AnalogIO-57661-US-MIB::wtWebGraphAnalog57661ReportEMailAddr
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.28.3.1.7.3.1.8.1 snmpget -v2c -c public <target> WebGraph-AnalogIO-57661-US-MIB::wtWebGraphAnalog57661ReportEMailAddr.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.5040.1.2.28.3.1.7.3.1.8.1 s <value>
Start monitoring WebGraph model 57661 analog I/O module (analog-channel reading/binary-threshold status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WebGraph-AnalogIO-57661-US-MIB::wtWebGraphAnalog57661ReportEMailAddr OID value, configure state conditions and alerts, and monitor any WebGraph model 57661 analog I/O module (analog-channel reading/binary-threshold status) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.5040 | wut | Com-Server-Intern-MIB |
| 1.3.6.1.4.1.5040.1 | wtComServer | Com-Server-Intern-MIB |
| 1.3.6.1.4.1.5040.1.2 | wtWebio | WebGraph-8xThermometer-US-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.5040.1.2.28 | wtWebGraphAnalog57661 | WebGraph-AnalogIO-57661-US-MIB |
| 1.3.6.1.4.1.5040.1.2.28.3 | wtWebGraphAnalog57661Config | WebGraph-AnalogIO-57661-US-MIB |
| 1.3.6.1.4.1.5040.1.2.28.3.1 | wtWebGraphAnalog57661Device | WebGraph-AnalogIO-57661-US-MIB |
| 1.3.6.1.4.1.5040.1.2.28.3.1.7 | wtWebGraphAnalog57661Report | WebGraph-AnalogIO-57661-US-MIB |
| 1.3.6.1.4.1.5040.1.2.28.3.1.7.3 | wtWebGraphAnalog57661ReportTable | WebGraph-AnalogIO-57661-US-MIB |
| 1.3.6.1.4.1.5040.1.2.28.3.1.7.3.1 | wtWebGraphAnalog57661ReportEntry | WebGraph-AnalogIO-57661-US-MIB |
| 1.3.6.1.4.1.5040.1.2.28.3.1.7.3.1.8 | wtWebGraphAnalog57661ReportEMailAddr | WebGraph-AnalogIO-57661-US-MIB |