WebGraph-AnalogIO-57661-US-MIB :: wtWebGraphAnalog57661BinaryTcpClientHysteresis1

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › WebGraph-AnalogIO-57661-US-MIB › wtWebGraphAnalog57661BinaryTcpClientHysteresis1

wtWebGraphAnalog57661BinaryTcpClientHysteresis1

Module: WebGraph-AnalogIO-57661-US-MIB

OID (symbolic): WebGraph-AnalogIO-57661-US-MIB::wtWebGraphAnalog57661BinaryTcpClientHysteresis1

OID (numeric): 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.25

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-write

Description: A change greater than this value initiate a transmission of the corresponding input value. The input 1 must be selected at wtWebGraphAnalog57661BinaryTcpClientInputTrigger. With a hysteresis of zero any change will be transmitted.

What is wtWebGraphAnalog57661BinaryTcpClientHysteresis1?

The minimum change in analog input 1's reading that must occur, in TCP Client mode, before the device sends an update to the remote server; input 1 must be selected in wtWebGraphAnalog57661BinaryTcpClientInputTrigger.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.25
snmpwalk -v2c -c public <target> WebGraph-AnalogIO-57661-US-MIB::wtWebGraphAnalog57661BinaryTcpClientHysteresis1

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.25.1
snmpget -v2c -c public <target> WebGraph-AnalogIO-57661-US-MIB::wtWebGraphAnalog57661BinaryTcpClientHysteresis1.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.25.1 s <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> wtWebGraphAnalog57661BinaryTcpClientHysteresis1.1

Start monitoring WebGraph model 57661 analog I/O module (analog-channel reading/binary-threshold status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WebGraph-AnalogIO-57661-US-MIB::wtWebGraphAnalog57661BinaryTcpClientHysteresis1 OID value, configure state conditions and alerts, and monitor any WebGraph model 57661 analog I/O module (analog-channel reading/binary-threshold status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5040wutCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1wtComServerCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1.2wtWebioWebGraph-8xThermometer-US-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5040.1.2.28wtWebGraphAnalog57661WebGraph-AnalogIO-57661-US-MIB
1.3.6.1.4.1.5040.1.2.28.3wtWebGraphAnalog57661ConfigWebGraph-AnalogIO-57661-US-MIB
1.3.6.1.4.1.5040.1.2.28.3.1wtWebGraphAnalog57661DeviceWebGraph-AnalogIO-57661-US-MIB
1.3.6.1.4.1.5040.1.2.28.3.1.3wtWebGraphAnalog57661BasicWebGraph-AnalogIO-57661-US-MIB
1.3.6.1.4.1.5040.1.2.28.3.1.3.9wtWebGraphAnalog57661BinaryWebGraph-AnalogIO-57661-US-MIB
1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3wtWebGraphAnalog57661BinaryTableWebGraph-AnalogIO-57661-US-MIB
1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1wtWebGraphAnalog57661BinaryEntryWebGraph-AnalogIO-57661-US-MIB
1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.25wtWebGraphAnalog57661BinaryTcpClientHysteresis1WebGraph-AnalogIO-57661-US-MIB