WebGraph-Air-Quality-US-MIB :: wtWebGraphAirQualitySessCntrlConfigPassword

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › WebGraph-Air-Quality-US-MIB › wtWebGraphAirQualitySessCntrlConfigPassword

wtWebGraphAirQualitySessCntrlConfigPassword

Module: WebGraph-Air-Quality-US-MIB

OID (symbolic): WebGraph-Air-Quality-US-MIB::wtWebGraphAirQualitySessCntrlConfigPassword

OID (numeric): 1.3.6.1.4.1.5040.1.2.35.2.5

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-write

Description: This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer.

What is wtWebGraphAirQualitySessCntrlConfigPassword?

Holds the configurator-level password, which can be changed by either the administrator or the configurator, and protects access to variables requiring configurator rights. Like the admin password, it defaults to "public" if never explicitly set, and reading it returns a null value rather than the actual password.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.35.2.5
snmpwalk -v2c -c public <target> WebGraph-Air-Quality-US-MIB::wtWebGraphAirQualitySessCntrlConfigPassword

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.35.2.5.1
snmpget -v2c -c public <target> WebGraph-Air-Quality-US-MIB::wtWebGraphAirQualitySessCntrlConfigPassword.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5040.1.2.35.2.5.1 s <value>

Start monitoring WebGraph networked environmental/air-quality sensor appliance (per-sensor reading/threshold-alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WebGraph-Air-Quality-US-MIB::wtWebGraphAirQualitySessCntrlConfigPassword OID value, configure state conditions and alerts, and monitor any WebGraph networked environmental/air-quality sensor appliance (per-sensor reading/threshold-alarm status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5040wutCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1wtComServerCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1.2wtWebioWebGraph-8xThermometer-US-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5040.1.2.35wtWebGraphAirQualityWebGraph-Air-Quality-US-MIB
1.3.6.1.4.1.5040.1.2.35.2wtWebGraphAirQualitySessCntrlWebGraph-Air-Quality-US-MIB
1.3.6.1.4.1.5040.1.2.35.2.5wtWebGraphAirQualitySessCntrlConfigPasswordWebGraph-Air-Quality-US-MIB