WebGraph-Air-Quality-US-MIB :: wtWebGraphAirQualityAlarmEMailAddr

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › WebGraph-Air-Quality-US-MIB › wtWebGraphAirQualityAlarmEMailAddr

wtWebGraphAirQualityAlarmEMailAddr

Module: WebGraph-Air-Quality-US-MIB

OID (symbolic): WebGraph-Air-Quality-US-MIB::wtWebGraphAirQualityAlarmEMailAddr

OID (numeric): 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.8

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-write

Description: E-Mail address for sending the alarm mail to.

What is wtWebGraphAirQualityAlarmEMailAddr?

Sets the email address that alarm number N's notification is sent to when the mail-enable bit in wtWebGraphAirQualityAlarmEnable is set.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.8
snmpwalk -v2c -c public <target> WebGraph-Air-Quality-US-MIB::wtWebGraphAirQualityAlarmEMailAddr

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.8.1
snmpget -v2c -c public <target> WebGraph-Air-Quality-US-MIB::wtWebGraphAirQualityAlarmEMailAddr.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.8.1 s <value>

Start monitoring WebGraph networked environmental/air-quality sensor appliance (per-sensor reading/threshold-alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WebGraph-Air-Quality-US-MIB::wtWebGraphAirQualityAlarmEMailAddr OID value, configure state conditions and alerts, and monitor any WebGraph networked environmental/air-quality sensor appliance (per-sensor reading/threshold-alarm status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5040wutCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1wtComServerCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1.2wtWebioWebGraph-8xThermometer-US-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5040.1.2.35wtWebGraphAirQualityWebGraph-Air-Quality-US-MIB
1.3.6.1.4.1.5040.1.2.35.3wtWebGraphAirQualityConfigWebGraph-Air-Quality-US-MIB
1.3.6.1.4.1.5040.1.2.35.3.1wtWebGraphAirQualityDeviceWebGraph-Air-Quality-US-MIB
1.3.6.1.4.1.5040.1.2.35.3.1.5wtWebGraphAirQualityAlarmWebGraph-Air-Quality-US-MIB
1.3.6.1.4.1.5040.1.2.35.3.1.5.3wtWebGraphAirQualityAlarmTableWebGraph-Air-Quality-US-MIB
1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1wtWebGraphAirQualityAlarmEntryWebGraph-Air-Quality-US-MIB
1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.8wtWebGraphAirQualityAlarmEMailAddrWebGraph-Air-Quality-US-MIB