WISI-GTMODULES-MIB :: gtModuleUptime

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › WISI-GTMODULES-MIB › gtModuleUptime

gtModuleUptime

Module: WISI-GTMODULES-MIB

OID (symbolic): WISI-GTMODULES-MIB::gtModuleUptime

OID (numeric): 1.3.6.1.4.1.7465.20.2.9.1.2.1.3.1.6

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The gtModule entity represents the current uptime of a SFM/MFM module within the GT01/GN50 rack unit.

What is gtModuleUptime?

The current uptime, in seconds, of this module since its last reboot. An admin checks this to see how recently a module restarted, which is useful when correlating a service disruption with an unexpected module reboot.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.7465.20.2.9.1.2.1.3.1.6
snmpwalk -v2c -c public <target> WISI-GTMODULES-MIB::gtModuleUptime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.7465.20.2.9.1.2.1.3.1.6.1
snmpget -v2c -c public <target> WISI-GTMODULES-MIB::gtModuleUptime.1

Start monitoring WISI GT-series headend module chassis, cable/CATV headend equipment (per-module hardware-ID/uptime/power-state status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WISI-GTMODULES-MIB::gtModuleUptime OID value, configure state conditions and alerts, and monitor any WISI GT-series headend module chassis, cable/CATV headend equipment (per-module hardware-ID/uptime/power-state status) from a single console.

How to Use in IPNetwork Monitor

Select a WISI GT-series headend module chassis, cable/CATV headend equipment (per-module hardware-ID/uptime/power-state status) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type gtModuleUptime into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The gtModule entity represents the current uptime of a SFM/MFM module within the GT01/GN50 rack unit. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the value is unexpectedly low (e.g. under 10 minutes), since that indicates a recent, possibly unplanned, reboot or restart. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.7465wisiWISI-ROOT-MIB
1.3.6.1.4.1.7465.20equipmentWISI-ROOT-MIB
1.3.6.1.4.1.7465.20.2devicesWISI-ROOT-MIB
1.3.6.1.4.1.7465.20.2.9tangramWISI-ROOT-MIB
1.3.6.1.4.1.7465.20.2.9.1gtUnitWISI-TANGRAM-MIB
Numeric OIDNameModule
1.3.6.1.4.1.7465.20.2.9.1.2gtModulesMIBWISI-GTMODULES-MIB
1.3.6.1.4.1.7465.20.2.9.1.2.1gtModulesObjectsWISI-GTMODULES-MIB
1.3.6.1.4.1.7465.20.2.9.1.2.1.3gtModulesTableWISI-GTMODULES-MIB
1.3.6.1.4.1.7465.20.2.9.1.2.1.3.1gtModulesEntryWISI-GTMODULES-MIB
1.3.6.1.4.1.7465.20.2.9.1.2.1.3.1.6gtModuleUptimeWISI-GTMODULES-MIB