WESTERN-MULTIPLEX-RAD10006-MIB :: mgmtFan2TrapControl

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsWESTERN-MULTIPLEX-RAD10006-MIBmgmtFan2TrapControl

mgmtFan2TrapControl

Module: WESTERN-MULTIPLEX-RAD10006-MIB

OID (symbolic): WESTERN-MULTIPLEX-RAD10006-MIB::mgmtFan2TrapControl

OID (numeric): 1.3.6.1.4.1.3727.20.20.3.17

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This persistent variable controls whether the Agent will attempt to send the 'fan2Trap' trap whenever the FAN2 Unit has a transition of its FAN alarm.

The 'fan2Trap' trap is defined in this MIB definition file.

'no-trap' indicates that the NMU, should not generate any SNMP trap on any transition. This is the default value.

'send-trap-on-alarm-transition' indicates that the NMU will only generate a SNMP trap on the transition to the 'alarm' state.

'send-trap-on-normal-transition' indicates that the NMU will only generate a SNMP trap on the transition to the 'normal' state.

'send-trap-on-both-transitions' indicates that the NMU will generate a SNMP trap on any transition.

Whenever the SNMP Agent attempts to send the 'fan2Trap' trap, other checks described below may prohibit this trap from transmission.

Whenever this variable prohibits a trap from being sent, then 'trapFilteredSpecific' will be incremented.

This MIB variable is the first of four checks that the NMU Agent uses to filter traps, based upon 1) a specific enable or disable control variable; 2) 'trapControl' which offers a gross on/off/limit control; 3) 'trapMgrTable' with 'trapMgrControl' and 'trapMgrAddress' which filters whether enterprise traps (such as this trap) and/or standard (RFC 1215) traps are sent to each specific trap manager; and 4) 'trapSeverityFilter' which filters traps according to a controlling severity variable for the specific trap, which in this case is described below, and is defined as 'mgmtFan2Severity'.

Whenever any of these trap filters cause a trap to be filtered, the corresponding MIB statistic is incremented. These statistics are 'trapFilteredSpecific', 'trapFilteredControl', 'trapFilteredManager', and 'trapFilteredSeverity'.

See the MIB descriptions (in this file, and in 'westmux.mib' file) for any of these above variables for details.

What is mgmtFan2TrapControl?

This controls whether and when the agent sends the 'fan2Trap' trap on a transition of fan 2's alarm condition: no-trap(1, the default), send-trap-on-alarm-transition(2), send-trap-on-normal-transition(3), or send-trap-on-both-transitions(4). Suppression by this specific object increments 'trapFilteredSpecific'.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3727.20.20.3.17
snmpwalk -v2c -c public <target> WESTERN-MULTIPLEX-RAD10006-MIB::mgmtFan2TrapControl

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3727.20.20.3.17.1
snmpget -v2c -c public <target> WESTERN-MULTIPLEX-RAD10006-MIB::mgmtFan2TrapControl.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.3727.20.20.3.17.1 i <value>

Start monitoring Western Multiplex Tsunami/RAD-10006 microwave radio links (T1-line/loopback/Ethernet-interface status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WESTERN-MULTIPLEX-RAD10006-MIB::mgmtFan2TrapControl OID value, configure state conditions and alerts, and monitor any Western Multiplex Tsunami/RAD-10006 microwave radio links (T1-line/loopback/Ethernet-interface status) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3727western_multiplexWESTERN-MULTIPLEX-MIB
1.3.6.1.4.1.3727.20tsunami100_06WESTERN-MULTIPLEX-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3727.20.20radioWESTERN-MULTIPLEX-RAD10006-MIB
1.3.6.1.4.1.3727.20.20.3mgmtWESTERN-MULTIPLEX-RAD10006-MIB
1.3.6.1.4.1.3727.20.20.3.17mgmtFan2TrapControlWESTERN-MULTIPLEX-RAD10006-MIB