Module: WESTERN-MULTIPLEX-MIB

OID (symbolic): WESTERN-MULTIPLEX-MIB::logTrapHysteresis

OID (numeric): 1.3.6.1.4.1.3727.20.10.4.31

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This persistent variable indicates the desired hysteresis time value that allows the logging sub-system to generate a SNMP generic log trap, called 'logGenericTrap'. System events that are qualified as having an associated specific trap will NOT be allowed to generate a second generic trap.

This control, allows a system event to be NORMALIZED within the 'logTrapHysteresis' time limit. If the event is not normlized, then the 'logGenericTrap' will be sent if not filtered by 'logTrapSeverityFilter', which also controls the generation of this trap. In addition trap management controls may filter this trap from being sent.

'logTrapSeverityFilter', may restrict the generation of a trap based upon the severity level as specified in 'logRecSeverity'.

The units are in seconds with the default value value of 120 which is the maximum allowed. The value of 0 is the minimum, which allows the trap to be generated immediately. The timing resolution is plus/minus 15 seconds.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3727.20.10.4.31
snmpwalk -v2c -c public <target> WESTERN-MULTIPLEX-MIB::logTrapHysteresis

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3727.20.10.4.31.1
snmpget -v2c -c public <target> WESTERN-MULTIPLEX-MIB::logTrapHysteresis.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.3727.20.10.4.31.1 i <value>

Start monitoring Western Multiplex (Proxim/BridgeWave) fixed-wireless microwave radio equipment (component-inventory/boot-history/event-log status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WESTERN-MULTIPLEX-MIB::logTrapHysteresis OID value, configure state conditions and alerts, and monitor any Western Multiplex (Proxim/BridgeWave) fixed-wireless microwave radio equipment (component-inventory/boot-history/event-log status) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3727western_multiplexWESTERN-MULTIPLEX-MIB
1.3.6.1.4.1.3727.20tsunami100_06WESTERN-MULTIPLEX-MIB
1.3.6.1.4.1.3727.20.10systemWESTERN-MULTIPLEX-MIB
1.3.6.1.4.1.3727.20.10.4logWESTERN-MULTIPLEX-MIB
1.3.6.1.4.1.3727.20.10.4.31logTrapHysteresisWESTERN-MULTIPLEX-MIB