| OID symbolic | OID numeric | Type | Access | Description |
| websense | 1.3.6.1.4.1.23365 | | | Websense Appliance SNMP |
| appliance | 1.3.6.1.4.1.23365.10000 | | | |
| NTF testEvent | 1.3.6.1.4.1.23365.10000.0.10 | | | Websense Alert: this event is for testing use |
| NTF cpuMaxUsageExceed | 1.3.6.1.4.1.23365.10000.0.1000 | | | Websense Alert: high CPU usage |
| NTF memMaxUsageExceed | 1.3.6.1.4.1.23365.10000.0.1001 | | | Websense Alert: high memory usage |
| NTF networkMaxBandwidthExceed | 1.3.6.1.4.1.23365.10000.0.1002 | | | Websense Alert: heavy network traffic on interface |
| NTF diskFreeMinSizeExceed | 1.3.6.1.4.1.23365.10000.0.1003 | | | Websense Alert: low free disk space |
| NTF swapMinFreeExceed | 1.3.6.1.4.1.23365.10000.0.1004 | | | Websense Alert: low free swap space |
| NTF systemLoad | 1.3.6.1.4.1.23365.10000.0.1005 | | | Websense Alert: heavy system load |
| NTF logFileMaxSizeExceed | 1.3.6.1.4.1.23365.10000.0.1006 | | | Websense Alert: too large log file size |
| NTF logCacheMinFreeExceed | 1.3.6.1.4.1.23365.10000.0.1007 | | | Websense Alert: low free log cache space |
| NTF moduleDown | 1.3.6.1.4.1.23365.10000.0.1050 | | | Websense Alert: appliance module down |
| NTF serviceDown | 1.3.6.1.4.1.23365.10000.0.1051 | | | Websense Alert: appliance service down |
| NTF backupFailure | 1.3.6.1.4.1.23365.10000.0.1052 | | | Websense Alert: appliance backup failure |
| NTF logServerConnectionLost | 1.3.6.1.4.1.23365.10000.0.1053 | | | Websense Alert: log server connection lost |
| NTF hostnameChange | 1.3.6.1.4.1.23365.10000.0.1061 | | | Websense Alert: appliance hostname changed |
| NTF ipAddressChange | 1.3.6.1.4.1.23365.10000.0.1062 | | | Websense Alert: appliance IP address changed |
| NTF powerSupply | 1.3.6.1.4.1.23365.10000.0.2001 | | | Websense Alert: appliance power supply warning |
| NTF redundancy | 1.3.6.1.4.1.23365.10000.0.2002 | | | Websense Alert: appliance redundancy warning |
| NTF temps | 1.3.6.1.4.1.23365.10000.0.2003 | | | Websense Alert: appliance temperatures warning |
| NTF fans | 1.3.6.1.4.1.23365.10000.0.2004 | | | Websense Alert: appliance fans warning |
| NTF volt | 1.3.6.1.4.1.23365.10000.0.2005 | | | Websense Alert: appliance voltages warning |
| NTF logs | 1.3.6.1.4.1.23365.10000.0.2006 | | | Websense Alert: appliance logs warning |
| NTF mem | 1.3.6.1.4.1.23365.10000.0.2007 | | | Websense Alert: appliance memory warning |
| NTF intrusion | 1.3.6.1.4.1.23365.10000.0.2008 | | | Websense Alert: appliance chassis intrusion detected |
| NTF battery | 1.3.6.1.4.1.23365.10000.0.2009 | | | Websense Alert: appliance battery warning |
| NTF raid | 1.3.6.1.4.1.23365.10000.0.2010 | | | Websense Alert: appliance RAID controller warning |
| STR moduleName | 1.3.6.1.4.1.23365.10000.1 | DisplayString | read-only | The name of current module: Appliance Controller, Websense Content Gateway, Websense Web Security, Network Agent, Websense Email Security Gateway |
| INT memUsageFlagEx | 1.3.6.1.4.1.23365.10000.2 | INTEGER | read-only | The flag to indicate memory usage exceed |
| vmTable | 1.3.6.1.4.1.23365.10000.3 | | not-accessible | A list of virtual machines. |
| vmEntry | 1.3.6.1.4.1.23365.10000.3.1 | | not-accessible | A concept row of virtual machine table. |
| INT vmStatus | 1.3.6.1.4.1.23365.10000.3.1.1 | INTEGER | read-only | The status of virtual machine. |
| STR vmName | 1.3.6.1.4.1.23365.10000.3.1.2 | DisplayString | read-only | The name of virtual machine. |
| hostname | 1.3.6.1.4.1.23365.10000.4 | | | |
| INT hostnameChangeFlag | 1.3.6.1.4.1.23365.10000.4.1 | INTEGER | read-only | The flag to indicate hostname change. |
| STR prevHostname | 1.3.6.1.4.1.23365.10000.4.2 | DisplayString | read-only | The hostname before changed. |
| STR currHostname | 1.3.6.1.4.1.23365.10000.4.3 | DisplayString | read-only | The current hostname. |
| ifaTable | 1.3.6.1.4.1.23365.10000.5 | | not-accessible | A list of monitoring interface IP addresses. |
| ifaEntry | 1.3.6.1.4.1.23365.10000.5.1 | | not-accessible | A concept row of monitoring interface IP address table. |
| INT ifaChangeFlag | 1.3.6.1.4.1.23365.10000.5.1.1 | INTEGER | read-only | The flag to indicate whether the IP address of monitoring interface has been changed. |
| STR ifaName | 1.3.6.1.4.1.23365.10000.5.1.2 | DisplayString | read-only | The name of monitoring interface. |
| STR ifaPrevAddress | 1.3.6.1.4.1.23365.10000.5.1.3 | DisplayString | read-only | The previous IP address of monitoring interface. |
| STR ifaCurrAddress | 1.3.6.1.4.1.23365.10000.5.1.4 | DisplayString | read-only | The current IP address of monitoring interface. |
| INT ifaSpeed | 1.3.6.1.4.1.23365.10000.5.1.5 | INTEGER | read-only | The speed of monitoring interface. |
| INT ifaInboundExceedFlag | 1.3.6.1.4.1.23365.10000.5.1.6 | INTEGER | read-only | The flag to indicate whether the inbound network traffic of monitoring interface exceeds its threhold. |
| INT ifaOutboundExceedFlag | 1.3.6.1.4.1.23365.10000.5.1.7 | INTEGER | read-only | The flag to indicate whether the outbound network traffic of monitoring interface exceeds its threhold. |
| STR ifaPhysAddress | 1.3.6.1.4.1.23365.10000.5.1.8 | DisplayString | read-only | The physical address of monitoring interface. |
| INT ifaChangeFlagv6 | 1.3.6.1.4.1.23365.10000.5.1.9 | INTEGER | read-only | The flag to indicate whether the IPv6 address of monitoring interface has been changed. |
| STR ifaPrevAddressv6 | 1.3.6.1.4.1.23365.10000.5.1.10 | DisplayString | read-only | The previous IPv6 address of monitoring interface. |
| STR ifaCurrAddressv6 | 1.3.6.1.4.1.23365.10000.5.1.11 | DisplayString | read-only | The current IPv6 address of monitoring interface. |
| raidStatus | 1.3.6.1.4.1.23365.10000.6 | | | |
| INT raidErrorFlag | 1.3.6.1.4.1.23365.10000.6.1 | INTEGER | read-only | The flag is set when disk error is detected. |
| STR dskPhysicalNr | 1.3.6.1.4.1.23365.10000.6.2 | DisplayString | read-only | The number of physical disks in the RAID controller. |
| STR dskCriticalNr | 1.3.6.1.4.1.23365.10000.6.3 | DisplayString | read-only | The number of physical disks in critical state. |
| STR dskFailedNr | 1.3.6.1.4.1.23365.10000.6.4 | DisplayString | read-only | The number of physical disks in failed state. |
| STR dskPhysErrMsg | 1.3.6.1.4.1.23365.10000.6.5 | DisplayString | read-only | The error message to describe the abnormal state of physical disks. |
| STR dskVirtualNr | 1.3.6.1.4.1.23365.10000.6.6 | DisplayString | read-only | The number of virtual drives in the RAID controller. |
| STR dskDegradedNr | 1.3.6.1.4.1.23365.10000.6.7 | DisplayString | read-only | The number of degraded virtual drives. |
| STR dskOfflineNr | 1.3.6.1.4.1.23365.10000.6.8 | DisplayString | read-only | The number of offline virtual drives. |
| svcTable | 1.3.6.1.4.1.23365.10000.7 | | not-accessible | A list of service entries. |
| svcEntry | 1.3.6.1.4.1.23365.10000.7.1 | | not-accessible | A concept row of service table. |
| INT svcStatus | 1.3.6.1.4.1.23365.10000.7.1.1 | INTEGER | read-only | The status of service. |
| STR svcName | 1.3.6.1.4.1.23365.10000.7.1.2 | DisplayString | read-only | The name of service. |
| loadAvg | 1.3.6.1.4.1.23365.10000.8 | | | |
| INT loadErrorFlag | 1.3.6.1.4.1.23365.10000.8.1 | INTEGER | read-only | The flag is set when load average limit is met. |
| STR loadName | 1.3.6.1.4.1.23365.10000.8.2 | DisplayString | read-only | The load name. |
| STR loadErrorMessage | 1.3.6.1.4.1.23365.10000.8.3 | DisplayString | read-only | The message to describe current load error. |
| wsAlert | 1.3.6.1.4.1.23365.10000.9 | | | |
| STR wsAlertMessage | 1.3.6.1.4.1.23365.10000.9.1 | DisplayString | read-only | The detailed message to describe current alert. |
| evtInfo | 1.3.6.1.4.1.23365.10000.10 | | | |
| STR evtTimestamp | 1.3.6.1.4.1.23365.10000.10.1 | DisplayString | read-only | Timestamp when current event occurred |
| INT evtDir | 1.3.6.1.4.1.23365.10000.10.2 | INTEGER | read-only | The direction of the event |
| STR evtSensor | 1.3.6.1.4.1.23365.10000.10.3 | DisplayString | read-only | The name of sensor: Power Supply, Temperature, Fan, Voltage, System ACPI Power State, Event Logging Disabled, Physical Security (Chassis
Intrusion), Battery |
| STR evtDesc | 1.3.6.1.4.1.23365.10000.10.4 | DisplayString | read-only | The name of current event |
| STR triggerReading | 1.3.6.1.4.1.23365.10000.10.5 | DisplayString | read-only | The trigger reading of sensor |
| STR triggerThreshold | 1.3.6.1.4.1.23365.10000.10.6 | DisplayString | read-only | The threshold to trigger this event |
| errorClear | 1.3.6.1.4.1.23365.10000.10000 | | | |
| NTF cpuMaxUsageExceedClear | 1.3.6.1.4.1.23365.10000.10000.0.1000 | | | Websense Alert: 'high CPU usage' is cleared |
| NTF memMaxUsageExceedClear | 1.3.6.1.4.1.23365.10000.10000.0.1001 | | | Websense Alert: 'high memory usage' is cleared |
| NTF networkMaxBandwidthExceedClear | 1.3.6.1.4.1.23365.10000.10000.0.1002 | | | Websense Alert: 'heavy network traffic on interface' is cleared |
| NTF diskFreeMinSizeExceedClear | 1.3.6.1.4.1.23365.10000.10000.0.1003 | | | Websense Alert: 'low free disk space' is cleared |
| NTF swapMinFreeExceedClear | 1.3.6.1.4.1.23365.10000.10000.0.1004 | | | Websense Alert: 'low free swap space' is cleared |
| NTF systemLoadClear | 1.3.6.1.4.1.23365.10000.10000.0.1005 | | | Websense Alert: 'heavy system load' is cleared |
| NTF logFileMaxSizeExceedClear | 1.3.6.1.4.1.23365.10000.10000.0.1006 | | | Websense Alert: 'too large log file size' is cleared |
| NTF logCacheMinFreeExceedClear | 1.3.6.1.4.1.23365.10000.10000.0.1007 | | | Websense Alert: 'low free log cache space' is cleared |
| NTF moduleDownClear | 1.3.6.1.4.1.23365.10000.10000.0.1050 | | | Websense Alert: 'appliance module down' is cleared |
| NTF serviceDownClear | 1.3.6.1.4.1.23365.10000.10000.0.1051 | | | Websense Alert: 'appliance service down' is cleared |
| NTF logServerConnectionLostClear | 1.3.6.1.4.1.23365.10000.10000.0.1053 | | | Websense Alert: 'log server connection lost' is cleared |
| NTF powerSupplyClear | 1.3.6.1.4.1.23365.10000.10000.0.2001 | | | Websense Alert: 'appliance power supply warning' is cleared |
| NTF redundancyClear | 1.3.6.1.4.1.23365.10000.10000.0.2002 | | | Websense Alert: 'appliance redundancy warning' is cleared |
| NTF tempsClear | 1.3.6.1.4.1.23365.10000.10000.0.2003 | | | Websense Alert: 'appliance temperatures warning' is cleared |
| NTF fansClear | 1.3.6.1.4.1.23365.10000.10000.0.2004 | | | Websense Alert: 'appliance fans warning' is cleared |
| NTF voltClear | 1.3.6.1.4.1.23365.10000.10000.0.2005 | | | Websense Alert: 'appliance voltages warning' is cleared |
| NTF logsClear | 1.3.6.1.4.1.23365.10000.10000.0.2006 | | | Websense Alert: 'appliance logs warning' is cleared |
| NTF memClear | 1.3.6.1.4.1.23365.10000.10000.0.2007 | | | Websense Alert: 'appliance memory warning' is cleared |
| NTF intrusionClear | 1.3.6.1.4.1.23365.10000.10000.0.2008 | | | Websense Alert: 'appliance chassis intrusion detected' is cleared |
| NTF batteryClear | 1.3.6.1.4.1.23365.10000.10000.0.2009 | | | Websense Alert: 'appliance battery warning' is cleared |
| NTF raidClear | 1.3.6.1.4.1.23365.10000.10000.0.2010 | | | Websense Alert: 'appliance RAID controller warning' is cleared |