All MIBs › VINA-MIB › frDlcmiPollingInterval
frDlcmiPollingInterval
Module: VINA-MIB
OID (symbolic): VINA-MIB::frDlcmiPollingInterval
OID (numeric): 1.3.6.1.2.1.10.32.1.1.5
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: This is the number of seconds between succes- sive status enquiry messages.
What is frDlcmiPollingInterval?
The number of seconds between successive LMI status enquiry messages sent on this interface, defaulting to 10, per its DESCRIPTION (Timer T391 in the referenced standard). Admins tune this if the carrier's frame-relay switch expects a different polling cadence than the default.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.2.1.10.32.1.1.5 snmpwalk -v2c -c public <target> VINA-MIB::frDlcmiPollingInterval
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.2.1.10.32.1.1.5.1 snmpget -v2c -c public <target> VINA-MIB::frDlcmiPollingInterval.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.2.1.10.32.1.1.5.1 i <value>
Start monitoring Vina Technologies network appliances with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the VINA-MIB::frDlcmiPollingInterval OID value, configure state conditions and alerts, and monitor any Vina Technologies network appliances from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.2 | mgmt | AXON-MIB |
| 1.3.6.1.2.1 | mib_2 | AXON-MIB |
| 1.3.6.1.2.1.10 | transmission | CHECKPOINT-MIB-2 |
| 1.3.6.1.2.1.10.32 | frameRelayDTE | FRAME-RELAY-DTE-MIB |
| 1.3.6.1.2.1.10.32.1 | frDlcmiTable | FRAME-RELAY-DTE-MIB |
| 1.3.6.1.2.1.10.32.1.1 | frDlcmiEntry | FRAME-RELAY-DTE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.2.1.10.32.1.1.5 | frDlcmiPollingInterval | VINA-MIB |