VIDEOFRAME-SIGMON-VM0010-MIB :: vm0010Active

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › VIDEOFRAME-SIGMON-VM0010-MIB › vm0010Active

vm0010Active

Module: VIDEOFRAME-SIGMON-VM0010-MIB

OID (symbolic): VIDEOFRAME-SIGMON-VM0010-MIB::vm0010Active

OID (numeric): 1.3.6.1.4.1.4596.4.2.1.10.1.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Indicates whether this entry is active (this module is in this slot).

What is vm0010Active?

This enumerated value (active or inactive) indicates whether a VM0010 module is actually present and running in the slot this entry represents. An admin checks it to confirm a module is physically installed and operating before trying to read or configure its other parameters. For example, a value of inactive(2) for a slot expected to hold a module would prompt the admin to check for a missing or failed card.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4596.4.2.1.10.1.1.2
snmpwalk -v2c -c public <target> VIDEOFRAME-SIGMON-VM0010-MIB::vm0010Active

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4596.4.2.1.10.1.1.2.1
snmpget -v2c -c public <target> VIDEOFRAME-SIGMON-VM0010-MIB::vm0010Active.1

Start monitoring Videoframe Systems VM0010 GPO relay module, broadcast/production signal monitoring equipment (relay open/closed status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the VIDEOFRAME-SIGMON-VM0010-MIB::vm0010Active OID value, configure state conditions and alerts, and monitor any Videoframe Systems VM0010 GPO relay module, broadcast/production signal monitoring equipment (relay open/closed status) from a single console.

How to Use in IPNetwork Monitor

Select a Videoframe Systems VM0010 GPO relay module, broadcast/production signal monitoring equipment (relay open/closed status) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type vm0010Active into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. Indicates whether this entry is active (this module is in this slot). On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is anything other than 'active', since that indicates the condition this object reports has changed to one worth investigating. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4596videoframeVIDEOFRAME-REGISTRATIONS-MIB
1.3.6.1.4.1.4596.4vfProductsVIDEOFRAME-REGISTRATIONS-MIB
1.3.6.1.4.1.4596.4.2vfSigmonFrameVIDEOFRAME-SIGMON-MIB
1.3.6.1.4.1.4596.4.2.1vfSigmonFrameModuleTypesVIDEOFRAME-SIGMON-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4596.4.2.1.10vm0010GPOInterfaceVIDEOFRAME-SIGMON-VM0010-MIB
1.3.6.1.4.1.4596.4.2.1.10.1vm0010TableVIDEOFRAME-SIGMON-VM0010-MIB
1.3.6.1.4.1.4596.4.2.1.10.1.1vm0010EntryVIDEOFRAME-SIGMON-VM0010-MIB
1.3.6.1.4.1.4596.4.2.1.10.1.1.2vm0010ActiveVIDEOFRAME-SIGMON-VM0010-MIB