VIDEOFRAME-SIGMON-VM0007-MIB :: vm0007Active

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › VIDEOFRAME-SIGMON-VM0007-MIB › vm0007Active

vm0007Active

Module: VIDEOFRAME-SIGMON-VM0007-MIB

OID (symbolic): VIDEOFRAME-SIGMON-VM0007-MIB::vm0007Active

OID (numeric): 1.3.6.1.4.1.4596.4.2.1.7.1.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Indicates whether this entry is active (this module is in this slot).

What is vm0007Active?

Reports whether a VM0007 Transfer Switch module is actually present and active in this slot, letting management software distinguish a populated slot from an empty or provisioned-but-missing one.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4596.4.2.1.7.1.1.2
snmpwalk -v2c -c public <target> VIDEOFRAME-SIGMON-VM0007-MIB::vm0007Active

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4596.4.2.1.7.1.1.2.1
snmpget -v2c -c public <target> VIDEOFRAME-SIGMON-VM0007-MIB::vm0007Active.1

Start monitoring Videoframe Systems VM0007 Transfer Switch module (video/audio source-switch status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the VIDEOFRAME-SIGMON-VM0007-MIB::vm0007Active OID value, configure state conditions and alerts, and monitor any Videoframe Systems VM0007 Transfer Switch module (video/audio source-switch status) from a single console.

How to Use in IPNetwork Monitor

Select a Videoframe Systems VM0007 Transfer Switch module (video/audio source-switch status) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type vm0007Active into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. Indicates whether this entry is active (this module is in this slot). On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is anything other than 'active', since that indicates the condition this object reports has changed to one worth investigating. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4596videoframeVIDEOFRAME-REGISTRATIONS-MIB
1.3.6.1.4.1.4596.4vfProductsVIDEOFRAME-REGISTRATIONS-MIB
1.3.6.1.4.1.4596.4.2vfSigmonFrameVIDEOFRAME-SIGMON-MIB
1.3.6.1.4.1.4596.4.2.1vfSigmonFrameModuleTypesVIDEOFRAME-SIGMON-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4596.4.2.1.7vm0007TransferSwitchVIDEOFRAME-SIGMON-VM0007-MIB
1.3.6.1.4.1.4596.4.2.1.7.1vm0007TableVIDEOFRAME-SIGMON-VM0007-MIB
1.3.6.1.4.1.4596.4.2.1.7.1.1vm0007EntryVIDEOFRAME-SIGMON-VM0007-MIB
1.3.6.1.4.1.4596.4.2.1.7.1.1.2vm0007ActiveVIDEOFRAME-SIGMON-VM0007-MIB