VDSL2-LINE-MIB :: xdsl2PMChCurr15MCorrectedBlocks

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsVDSL2-LINE-MIBxdsl2PMChCurr15MCorrectedBlocks

xdsl2PMChCurr15MCorrectedBlocks

Module: VDSL2-LINE-MIB

OID (symbolic): VDSL2-LINE-MIB::xdsl2PMChCurr15MCorrectedBlocks

OID (numeric): 1.3.6.1.2.1.10.251.1.4.2.1.1.6

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: Count of FEC (FFEC for xTU-R) anomalies (corrected code words) occurring in the channel during the interval. This parameter is inhibited during UAS or SES. If the FEC is applied over multiple channels, then each related FEC (or FFEC) anomaly SHOULD increment each of the counters related to the individual channels.

What is xdsl2PMChCurr15MCorrectedBlocks?

This object counts the number of FEC (Forward Error Correction) corrected code words occurring in a VDSL2 channel during the current 15-minute performance measurement interval. Higher counts indicate more bit errors that were successfully repaired by the error correction algorithm. Line technicians use this metric to assess line quality; a rising trend suggests degrading signal conditions that may warrant investigation.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.10.251.1.4.2.1.1.6
snmpwalk -v2c -c public <target> VDSL2-LINE-MIB::xdsl2PMChCurr15MCorrectedBlocks

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.10.251.1.4.2.1.1.6.1
snmpget -v2c -c public <target> VDSL2-LINE-MIB::xdsl2PMChCurr15MCorrectedBlocks.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> xdsl2PMChCurr15MCorrectedBlocks.1

Start monitoring vendor-neutral, standards-based MIB, DSL access multiplexers (DSLAMs), VDSL2/ADSL modems and routers (line up/down/template/diagnostic status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the VDSL2-LINE-MIB::xdsl2PMChCurr15MCorrectedBlocks OID value, configure state conditions and alerts, and monitor any vendor-neutral, standards-based MIB, DSL access multiplexers (DSLAMs), VDSL2/ADSL modems and routers (line up/down/template/diagnostic status) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAXON-MIB
1.3.6.1.2.1mib_2AXON-MIB
1.3.6.1.2.1.10transmissionCHECKPOINT-MIB-2
Numeric OIDNameModule
1.3.6.1.2.1.10.251vdsl2MIBVDSL2-LINE-MIB
1.3.6.1.2.1.10.251.1xdsl2ObjectsVDSL2-LINE-MIB
1.3.6.1.2.1.10.251.1.4xdsl2PMVDSL2-LINE-MIB
1.3.6.1.2.1.10.251.1.4.2xdsl2PMChannelVDSL2-LINE-MIB
1.3.6.1.2.1.10.251.1.4.2.1xdsl2PMChCurrTableVDSL2-LINE-MIB
1.3.6.1.2.1.10.251.1.4.2.1.1xdsl2PMChCurrEntryVDSL2-LINE-MIB
1.3.6.1.2.1.10.251.1.4.2.1.1.6xdsl2PMChCurr15MCorrectedBlocksVDSL2-LINE-MIB