UX-OBJECTS-MIB :: uxSystemCoreSwitchTemp

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsUX-OBJECTS-MIBuxSystemCoreSwitchTemp

uxSystemCoreSwitchTemp

Module: UX-OBJECTS-MIB

OID (symbolic): UX-OBJECTS-MIB::uxSystemCoreSwitchTemp

OID (numeric): 1.3.6.1.4.1.177.15.1.12.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Provides core switch temperature (C).

What is uxSystemCoreSwitchTemp?

Read-only integer giving the temperature, in Celsius, of the system's core switch component (1-65535). Watch this for abnormal heat buildup that could indicate a cooling or airflow problem on the chassis.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.177.15.1.12.2
snmpwalk -v2c -c public <target> UX-OBJECTS-MIB::uxSystemCoreSwitchTemp

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.177.15.1.12.2.1
snmpget -v2c -c public <target> UX-OBJECTS-MIB::uxSystemCoreSwitchTemp.1

Start monitoring Sonus SBC 1000/2000 session border controller, net.com UX1000/UX2000 VoIP gateway chassis (chassis/alarm/DSP-resource status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the UX-OBJECTS-MIB::uxSystemCoreSwitchTemp OID value, configure state conditions and alerts, and monitor any Sonus SBC 1000/2000 session border controller, net.com UX1000/UX2000 VoIP gateway chassis (chassis/alarm/DSP-resource status) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.177netUX-OBJECTS-MIB
1.3.6.1.4.1.177.15uxUX-OBJECTS-MIB
1.3.6.1.4.1.177.15.1uxObjectsUX-OBJECTS-MIB
1.3.6.1.4.1.177.15.1.12uxSystemUX-OBJECTS-MIB
1.3.6.1.4.1.177.15.1.12.2uxSystemCoreSwitchTempUX-OBJECTS-MIB