Type: INTEGER

Access: read-only

Description: Provides Current (A) going out from the supply This information is returned in 1000s of the unit value

What is uxPSUCurrentOut?

Read-only integer giving the current, in amps, going out of this power supply, reported in thousandths of the actual unit (0-10000). Divide by 1000 for the real amperage when calculating the PSU's delivered load.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.177.15.1.9.1.10
snmpwalk -v2c -c public <target> UX-OBJECTS-MIB::uxPSUCurrentOut

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.177.15.1.9.1.10.1
snmpget -v2c -c public <target> UX-OBJECTS-MIB::uxPSUCurrentOut.1

Start monitoring Sonus SBC 1000/2000 session border controller, net.com UX1000/UX2000 VoIP gateway chassis (chassis/alarm/DSP-resource status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the UX-OBJECTS-MIB::uxPSUCurrentOut OID value, configure state conditions and alerts, and monitor any Sonus SBC 1000/2000 session border controller, net.com UX1000/UX2000 VoIP gateway chassis (chassis/alarm/DSP-resource status) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.177netUX-OBJECTS-MIB
1.3.6.1.4.1.177.15uxUX-OBJECTS-MIB
1.3.6.1.4.1.177.15.1uxObjectsUX-OBJECTS-MIB
1.3.6.1.4.1.177.15.1.9uxPSUTableUX-OBJECTS-MIB
1.3.6.1.4.1.177.15.1.9.1uxPSUEntryUX-OBJECTS-MIB
1.3.6.1.4.1.177.15.1.9.1.10uxPSUCurrentOutUX-OBJECTS-MIB