UBNT-EdgeMAX-MIB

MIB Reference — IPNetwork Monitor

All MIBsUBNT-EdgeMAX-MIB

Organization: Ubiquiti Networks, Inc.

Last Updated: 2018-01-03

Category: Ubiquiti Networks

Description:

Monitors Ubiquiti EdgeMAX router and switch performance, interface stats, and routing information.

Imported Objects

From SNMPv2-CONF

MODULE-COMPLIANCE
OBJECT-GROUP

From SNMPv2-SMI

Counter64
Gauge32
Integer32
IpAddress
MODULE-IDENTITY
OBJECT-TYPE
TimeTicks

From SNMPv2-TC

DisplayString
MacAddress
TruthValue

From UBNT-MIB

ubntEdgeMaxGroupsOBJECT-IDENTITY
ubntMIBMODULE-IDENTITY

What Is UBNT-EdgeMAX-MIB?

UBNT-EdgeMAX-MIB is Ubiquiti Networks' vendor MIB for its EdgeMAX line of routers and switches (EdgeRouter/EdgeSwitch), providing SNMP visibility into device performance and networking state. It generally exposes interface statistics, routing/forwarding information, and overall system performance metrics for these small-to-midsize business networking appliances. It supports monitoring of hardware/software status such as interface throughput and error counts, and general device performance, which administrators use to catch link flaps, packet loss, or resource strain on the router/switch. It builds on standard IF-MIB and SNMPv2-SMI conventions typical of vendor-neutral interface monitoring, extended with EdgeMAX-specific objects. It is typically deployed in small business or prosumer network environments running EdgeOS on Ubiquiti EdgeRouter or EdgeSwitch hardware, where UBNT-EdgeMAX-MIB SNMP monitoring helps catch link flaps and resource strain early.

IPNetwork Monitor allows you to monitor SNMP objects defined in UBNT-EdgeMAX-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

What Can Be Monitored

  • interface performance statistics
  • routing information
  • general device performance metrics

Supported Devices

  • Ubiquiti EdgeRouter
  • Ubiquiti EdgeSwitch

Monitoring Examples

No sample object names were provided for this MIB, so specifics beyond the general interface and routing statistics described in its module description cannot be grounded further; a typical use would be polling interface tables for packet/error counters to detect a flapping WAN link or an overloaded switch port, but exact table/object names should be confirmed against the actual MIB source.

OIDs
OID symbolicOID numericTypeAccessDescription
ubntEdgeMax1.3.6.1.4.1.41112.1.5The EdgeMax MIB module for Ubiquiti Networks, Inc. entities
ubntProductIdent1.3.6.1.4.1.41112.1.5.1
STR ubntModel1.3.6.1.4.1.41112.1.5.1.1DisplayStringread-onlyProduct model.
STR ubntSerialNumber1.3.6.1.4.1.41112.1.5.1.2DisplayStringread-onlySerial number.
STR ubntVersion1.3.6.1.4.1.41112.1.5.1.3DisplayStringread-onlyFirmware version.
ubntPowerOuts1.3.6.1.4.1.41112.1.5.2
U32 ubntPowerOutsCount1.3.6.1.4.1.41112.1.5.2.1Unsigned32read-onlyThe number of power outputs present on this system.
ubntPowerOutTable1.3.6.1.4.1.41112.1.5.2.2not-accessibleA list of power out entries. The number of entries is given by the value of ubntPowerOutsCount.
ubntPowerOutEntry1.3.6.1.4.1.41112.1.5.2.2.1not-accessibleAn entry in the ubntPowerOutTable.
I32 ubntPowerOutIndex1.3.6.1.4.1.41112.1.5.2.2.1.1Integer32read-onlyA unique value for each power output.
I32 ubntPowerOutVoltage1.3.6.1.4.1.41112.1.5.2.2.1.2Integer32read-onlyOutput voltage in mV.
I32 ubntPowerOutCurrent1.3.6.1.4.1.41112.1.5.2.2.1.3Integer32read-onlyOutput current in mA.
I32 ubntPowerOutPower1.3.6.1.4.1.41112.1.5.2.2.1.4Integer32read-onlyOutput power in mW.
ubntPowerSupplies1.3.6.1.4.1.41112.1.5.3
U32 ubntPsuBaysNumber1.3.6.1.4.1.41112.1.5.3.1Unsigned32read-onlyThe number of PSU bays available on this system.
ubntPsuTable1.3.6.1.4.1.41112.1.5.3.2not-accessibleA list of PSU entries. The number of entries is given by the value of ubntPsuBaysNumber.
ubntPsuEntry1.3.6.1.4.1.41112.1.5.3.2.1not-accessibleAn entry in the ubntPsuTable.
I32 ubntPsuIndex1.3.6.1.4.1.41112.1.5.3.2.1.1Integer32read-onlyA unique value for each PSU.
INT ubntPsuType1.3.6.1.4.1.41112.1.5.3.2.1.2INTEGERread-onlyPSU Type.
INT ubntPsuStatus1.3.6.1.4.1.41112.1.5.3.2.1.3INTEGERread-onlyPSU Status.
INT ubntPsuOperStatus1.3.6.1.4.1.41112.1.5.3.2.1.4INTEGERread-onlyPSU operational status.
I32 ubntPsuVoltage1.3.6.1.4.1.41112.1.5.3.2.1.5Integer32read-onlyPSU voltage in mV.
I32 ubntPsuTemperature1.3.6.1.4.1.41112.1.5.3.2.1.6Integer32read-onlyPSU temperature in thousands of degrees Celsius.
INT ubntPsuCharging1.3.6.1.4.1.41112.1.5.3.2.1.7INTEGERread-onlyShows PSU charging state if it is supported.
I32 ubntPsuBatteryQuantity1.3.6.1.4.1.41112.1.5.3.2.1.8Integer32read-onlyNumber of batteries connected to PSU.
INT ubntPsuBatteryChargeLevel1.3.6.1.4.1.41112.1.5.3.2.1.9INTEGERread-onlyCurrent battery charge level as a percent (0-100%).
TIK ubntPsuBatteryTimeRemaining1.3.6.1.4.1.41112.1.5.3.2.1.10TimeTicksread-onlyThe battery run time remaining before battery exhaustion.
INT ubntPsuBatteryReplaceIndicator1.3.6.1.4.1.41112.1.5.3.2.1.11INTEGERread-onlyIndicates whether the batteries need replacing.
STR ubntPsuBatteryLastReplaceDate1.3.6.1.4.1.41112.1.5.3.2.1.12DisplayStringread-onlyBattery installation date (mm/dd/yyyy).
ubntThermometers1.3.6.1.4.1.41112.1.5.4
U32 ubntThermometersCount1.3.6.1.4.1.41112.1.5.4.1Unsigned32read-onlyThe number of installed thermometers on this system.
ubntThermsTable1.3.6.1.4.1.41112.1.5.4.2not-accessibleA list of thermometers entries. The number of entries is given by the value of ubntThermometersCount.
ubntThermsEntry1.3.6.1.4.1.41112.1.5.4.2.1not-accessibleAn entry in the ubntThermsTable.
I32 ubntThermIndex1.3.6.1.4.1.41112.1.5.4.2.1.1Integer32read-onlyA unique value for thermometer.
INT ubntThermType1.3.6.1.4.1.41112.1.5.4.2.1.2INTEGERread-onlyType of thermometer.
I32 ubntThermTemperature1.3.6.1.4.1.41112.1.5.4.2.1.3Integer32read-onlyTemperature in thousands of degrees Celsius.
ubntFans1.3.6.1.4.1.41112.1.5.5
U32 ubntFansCount1.3.6.1.4.1.41112.1.5.5.1Unsigned32read-onlyThe number of installed fans on this system.
ubntFansTable1.3.6.1.4.1.41112.1.5.5.2not-accessibleA list of fan entries. The number of entries is given by the value of ubntFansCount.
ubntFanEntry1.3.6.1.4.1.41112.1.5.5.2.1not-accessibleAn entry in the ubntFansTable.
I32 ubntFanIndex1.3.6.1.4.1.41112.1.5.5.2.1.1Integer32read-onlyA unique value for fan.
INT ubntFanType1.3.6.1.4.1.41112.1.5.5.2.1.2INTEGERread-onlyType of fan.
I32 ubntFanRpm1.3.6.1.4.1.41112.1.5.5.2.1.3Integer32read-onlyFan RPM.

RFC description

Product identification and power monitoring for Ubiquiti EdgeMax network devices.

Start monitoring Ubiquiti EdgeRouter, Ubiquiti EdgeSwitch (interface throughput/error counter status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download UBNT-EdgeMAX-MIB