The-v01-MIB :: inChStatus

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › The-v01-MIB › inChStatus

inChStatus

Module: The-v01-MIB

OID (symbolic): The-v01-MIB::inChStatus

OID (numeric): 1.3.6.1.4.1.18248.20.1.2.1.1.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: 0 = OK,1 = Not available,2 = over-flow,3 = under-flow,4=ERR

What is inChStatus?

This read-only value reports the health of one input channel on the Papouch TH2E sensor using coded values: 0 for OK, 1 for not available, 2 for over-flow, 3 for under-flow, and 4 for error. An admin checks this before trusting the paired inChValue reading, since any code other than OK means the channel's measurement is currently unreliable. For example, an inChStatus of 2 on a temperature channel means the probe's reading has exceeded the sensor's measurable range and inChValue should be disregarded until the status clears.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18248.20.1.2.1.1.1
snmpwalk -v2c -c public <target> The-v01-MIB::inChStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.18248.20.1.2.1.1.1.1
snmpget -v2c -c public <target> The-v01-MIB::inChStatus.1

Start monitoring HWg/Papouch THE networked temperature sensor (channel temperature reading/alarm-threshold status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the The-v01-MIB::inChStatus OID value, configure state conditions and alerts, and monitor any HWg/Papouch THE networked temperature sensor (channel temperature reading/alarm-threshold status) from a single console.

How to Use in IPNetwork Monitor

Select a HWg/Papouch THE networked temperature sensor (channel temperature reading/alarm-threshold status) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type inChStatus into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the current channel status: OK, not available, an over-flow condition, an under-flow condition, or an error. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value indicates anything other than OK, since an over-flow, under-flow, or error condition needs attention. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.18248papouchProjektPapouch-SMI
1.3.6.1.4.1.18248.20theTh2e-v01-MIB
1.3.6.1.4.1.18248.20.1version1Th2e-v01-MIB
1.3.6.1.4.1.18248.20.1.2table_channelTh2e-v01-MIB
1.3.6.1.4.1.18248.20.1.2.1channelTableTh2e-v01-MIB
1.3.6.1.4.1.18248.20.1.2.1.1channelEntryTh2e-v01-MIB
Numeric OIDNameModule