TN-THERMAL-PROTECTION-MIB :: tnThermalProtectionPriorityIndex

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › TN-THERMAL-PROTECTION-MIB › tnThermalProtectionPriorityIndex

tnThermalProtectionPriorityIndex

Module: TN-THERMAL-PROTECTION-MIB

OID (symbolic): TN-THERMAL-PROTECTION-MIB::tnThermalProtectionPriorityIndex

OID (numeric): 1.3.6.1.4.1.868.2.5.32.1.1.1.1.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The priority the port belongs to. 4 priorities are supported.

What is tnThermalProtectionPriorityIndex?

This read-only value identifies one of four supported thermal-protection priority levels (0 through 3) that a row in the priority table configures a shutdown temperature for. An administrator uses these priority levels, assigned to ports via tnThermalProtectionIfPriority, to decide which ports get turned off first as chip temperature rises. Priority 0 might be reserved for ports the admin wants to keep powered as long as possible.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.868.2.5.32.1.1.1.1.1
snmpwalk -v2c -c public <target> TN-THERMAL-PROTECTION-MIB::tnThermalProtectionPriorityIndex

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.868.2.5.32.1.1.1.1.1.1
snmpget -v2c -c public <target> TN-THERMAL-PROTECTION-MIB::tnThermalProtectionPriorityIndex.1

Start monitoring Transition Networks managed Ethernet switch, industrial media converter (per-port temperature/shutdown status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TN-THERMAL-PROTECTION-MIB::tnThermalProtectionPriorityIndex OID value, configure state conditions and alerts, and monitor any Transition Networks managed Ethernet switch, industrial media converter (per-port temperature/shutdown status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.868transitionTRANSITION-SMI
1.3.6.1.4.1.868.2productsTRANSITION-SMI
1.3.6.1.4.1.868.2.5tnProductsTRANSITION-SMI
Numeric OIDNameModule
1.3.6.1.4.1.868.2.5.32tnThermalProtectionMIBTN-THERMAL-PROTECTION-MIB
1.3.6.1.4.1.868.2.5.32.1tnThermalProtectionMIBObjectsTN-THERMAL-PROTECTION-MIB
1.3.6.1.4.1.868.2.5.32.1.1tnThermalProtectionMgmtTN-THERMAL-PROTECTION-MIB
1.3.6.1.4.1.868.2.5.32.1.1.1tnThermalProtectionPriorityTableTN-THERMAL-PROTECTION-MIB
1.3.6.1.4.1.868.2.5.32.1.1.1.1tnThermalProtectionPriorityEntryTN-THERMAL-PROTECTION-MIB
1.3.6.1.4.1.868.2.5.32.1.1.1.1.1tnThermalProtectionPriorityIndexTN-THERMAL-PROTECTION-MIB