All MIBs › TIMETRA-SAS-ALARM-INPUT-MIB › tmnxSasAlarmOutputSeverity
tmnxSasAlarmOutputSeverity
Module: TIMETRA-SAS-ALARM-INPUT-MIB
OID (symbolic): TIMETRA-SAS-ALARM-INPUT-MIB::tmnxSasAlarmOutputSeverity
OID (numeric): 1.3.6.1.4.1.6527.6.2.2.2.9.1.1.5
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Configured output severity of the alarm.
What is tmnxSasAlarmOutputSeverity?
This value sets the severity level, none(1), minor(2), major(3), or critical(4), reported when this alarm input triggers. Admins configure it to control how the resulting alarm is prioritized and displayed in the NMS, matching the real-world importance of the condition being monitored. Setting a smoke-detector input's severity to critical(4) would ensure it's flagged with the highest urgency when triggered.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6527.6.2.2.2.9.1.1.5 snmpwalk -v2c -c public <target> TIMETRA-SAS-ALARM-INPUT-MIB::tmnxSasAlarmOutputSeverity
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.6527.6.2.2.2.9.1.1.5.1 snmpget -v2c -c public <target> TIMETRA-SAS-ALARM-INPUT-MIB::tmnxSasAlarmOutputSeverity.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.6527.6.2.2.2.9.1.1.5.1 i <value>
Start monitoring Nokia/Alcatel-Lucent 7210 SAS service aggregation switch (external alarm-input contact status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TIMETRA-SAS-ALARM-INPUT-MIB::tmnxSasAlarmOutputSeverity OID value, configure state conditions and alerts, and monitor any Nokia/Alcatel-Lucent 7210 SAS service aggregation switch (external alarm-input contact status) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.6527 | timetra | ALCATEL-IND1-TIMETRA-GLOBAL-MIB |
| 1.3.6.1.4.1.6527.6 | tmnxBasedProducts | TIMETRA-GLOBAL-MIB |
| 1.3.6.1.4.1.6527.6.2 | timetraServiceAccessSwitches | TIMETRA-SAS-GLOBAL-MIB |
| 1.3.6.1.4.1.6527.6.2.2 | timetraSASMIB | TIMETRA-SAS-GLOBAL-MIB |
| 1.3.6.1.4.1.6527.6.2.2.2 | timetraSASObjs | TIMETRA-SAS-GLOBAL-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.6527.6.2.2.2.9 | tmnxSasAlarmInputObjs | TIMETRA-SAS-ALARM-INPUT-MIB |
| 1.3.6.1.4.1.6527.6.2.2.2.9.1 | tmnxSasAlarmInputInfoTable | TIMETRA-SAS-ALARM-INPUT-MIB |
| 1.3.6.1.4.1.6527.6.2.2.2.9.1.1 | tmnxSasAlarmInputInfoEntry | TIMETRA-SAS-ALARM-INPUT-MIB |
| 1.3.6.1.4.1.6527.6.2.2.2.9.1.1.5 | tmnxSasAlarmOutputSeverity | TIMETRA-SAS-ALARM-INPUT-MIB |