T1E1-OPT-MIB :: cdx6500VPCTT1E1CfgDS0Rate

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › T1E1-OPT-MIB › cdx6500VPCTT1E1CfgDS0Rate

cdx6500VPCTT1E1CfgDS0Rate

Module: T1E1-OPT-MIB

OID (symbolic): T1E1-OPT-MIB::cdx6500VPCTT1E1CfgDS0Rate

OID (numeric): 1.3.6.1.4.1.449.2.1.2.1.1.24.3.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Specifies the number of valid data bits within each DS0 for this port. ds056k : 7 bits of the DS0 contains data information, the 8th bit is used for 1's density. ds064k : All 8 bits of the DS0 contain data information. DS0 Rate for ports configured with port type `voice' is always 64K, while for ports configured with port type `data', it is 56K or 64K, the default being 56K. nc : Skipped during configuration.

What is cdx6500VPCTT1E1CfgDS0Rate?

This read-only object reports whether this channel's DS0 uses 56k (7 data bits with the 8th bit used for 1's-density robbing) or 64k (all 8 bits carrying data) encoding, with voice ports always fixed at 64k and data ports defaulting to 56k. Admins check it to confirm the correct data rate is configured, since selecting the wrong rate on a data channel can cause bit errors on links that require robbed-bit signaling. For example, cdx6500VPCTT1E1CfgDS0Rate reading ds056k(1) on a data port confirms the channel reserves the 8th bit of each DS0 for signaling robustness rather than carrying user data.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.24.3.1.5
snmpwalk -v2c -c public <target> T1E1-OPT-MIB::cdx6500VPCTT1E1CfgDS0Rate

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.24.3.1.5.1
snmpget -v2c -c public <target> T1E1-OPT-MIB::cdx6500VPCTT1E1CfgDS0Rate.1

Start monitoring Codex (Motorola Codex) 6500-series multiplexer/data communications chassis (T1/E1 virtual port mapping) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the T1E1-OPT-MIB::cdx6500VPCTT1E1CfgDS0Rate OID value, configure state conditions and alerts, and monitor any Codex (Motorola Codex) 6500-series multiplexer/data communications chassis (T1/E1 virtual port mapping) from a single console.

OID Breakdown

Upper-level ancestors (13 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.449codexALC-OPT-MIB
1.3.6.1.4.1.449.2cdxProductSpecificALC-OPT-MIB
1.3.6.1.4.1.449.2.1cdx6500ALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2cdx6500ConfigurationALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1cdx6500CfgProtocolGroupALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.1cdx6500PCTPortProtocolGroupALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.1.24cdx6500PCTT1E1PortTableCDX6500T1E1-OPT-SMI
Numeric OIDNameModule
1.3.6.1.4.1.449.2.1.2.1.1.24.3cdx6500VPCTT1E1PortTableT1E1-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.1.24.3.1cdx6500VPCTT1E1PortEntryT1E1-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.1.24.3.1.5cdx6500VPCTT1E1CfgDS0RateT1E1-OPT-MIB