T11-FC-RSCN-MIB :: t11FcRscnInScrs

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › T11-FC-RSCN-MIB › t11FcRscnInScrs

t11FcRscnInScrs

Module: T11-FC-RSCN-MIB

OID (symbolic): T11-FC-RSCN-MIB::t11FcRscnInScrs

OID (numeric): 1.3.6.1.2.1.161.1.2.1.1.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The number of SCRs received from Nx_Ports by this switch on this Fabric.

This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0.

What is t11FcRscnInScrs?

Counts the number of State Change Registration (SCR) requests this Fibre Channel switch has received from Nx_Ports on this fabric. An admin monitors this counter as a baseline measure of how many end devices are registering for RSCN notifications.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.161.1.2.1.1.1
snmpwalk -v2c -c public <target> T11-FC-RSCN-MIB::t11FcRscnInScrs

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.161.1.2.1.1.1.1
snmpget -v2c -c public <target> T11-FC-RSCN-MIB::t11FcRscnInScrs.1

Start monitoring Fibre Channel fabric switches, FC-LS RSCN support RFC 4983 (state-change notification volume/rejection status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the T11-FC-RSCN-MIB::t11FcRscnInScrs OID value, configure state conditions and alerts, and monitor any Fibre Channel fabric switches, FC-LS RSCN support RFC 4983 (state-change notification volume/rejection status) from a single console.

How to Use in IPNetwork Monitor

Select a Fibre Channel fabric switches, FC-LS RSCN support RFC 4983 (state-change notification volume/rejection status) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type t11FcRscnInScrs into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The number of SCRs received from Nx_Ports by this switch on this Fabric. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAPERTUS-NPG-MIB
1.3.6.1.2.1mib_2AXON-MIB
Numeric OIDNameModule
1.3.6.1.2.1.161t11FcRscnMIBT11-FC-RSCN-MIB
1.3.6.1.2.1.161.1t11FcRscnObjectsT11-FC-RSCN-MIB
1.3.6.1.2.1.161.1.2t11FcRscnStatsT11-FC-RSCN-MIB
1.3.6.1.2.1.161.1.2.1t11FcRscnStatsTableT11-FC-RSCN-MIB
1.3.6.1.2.1.161.1.2.1.1t11FcRscnStatsEntryT11-FC-RSCN-MIB
1.3.6.1.2.1.161.1.2.1.1.1t11FcRscnInScrsT11-FC-RSCN-MIB