SPSv1-MIB :: outletCfgPduCDelayOnTime

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SPSv1-MIB › outletCfgPduCDelayOnTime

outletCfgPduCDelayOnTime

Module: SPSv1-MIB

OID (symbolic): SPSv1-MIB::outletCfgPduCDelayOnTime

OID (numeric): 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The Delay On time of PduC outlet.

What is outletCfgPduCDelayOnTime?

This read-write integer, in seconds, sets how long a PduC outlet waits before turning on when its delay-on status is set to delay, used to sequence startup order on the C bank.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1.4
snmpwalk -v2c -c public <target> SPSv1-MIB::outletCfgPduCDelayOnTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1.4.1
snmpget -v2c -c public <target> SPSv1-MIB::outletCfgPduCDelayOnTime.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1.4.1 i <value>

Start monitoring Powertek/SPS-series rack PDU (firmware version/network configuration status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SPSv1-MIB::outletCfgPduCDelayOnTime OID value, configure state conditions and alerts, and monitor any Powertek/SPS-series rack PDU (firmware version/network configuration status) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.42610powertekSPSv1-MIB
1.3.6.1.4.1.42610.1productSPSv1-MIB
1.3.6.1.4.1.42610.1.4pduSPSv1-MIB
1.3.6.1.4.1.42610.1.4.4spsSPSv1-MIB
1.3.6.1.4.1.42610.1.4.4.1pduObjectsSPSv1-MIB
1.3.6.1.4.1.42610.1.4.4.1.6pduPwrMonitoringSPSv1-MIB
1.3.6.1.4.1.42610.1.4.4.1.6.2pduPwrMonitoringOutletSPSv1-MIB
1.3.6.1.4.1.42610.1.4.4.1.6.2.3pduPwrMonitoringOutletPduCSPSv1-MIB
1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3pduPwrMonitoringOutletCfgTablePduCSPSv1-MIB
1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1pduPwrMonitoringOutletCfgPduCEntrySPSv1-MIB
1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1.4outletCfgPduCDelayOnTimeSPSv1-MIB