All MIBs › SONUS-NODE-MIB › sonusNodeShelfStatFan
sonusNodeShelfStatFan
Module: SONUS-NODE-MIB
OID (symbolic): SONUS-NODE-MIB::sonusNodeShelfStatFan
OID (numeric): 1.3.6.1.4.1.2879.2.1.1.1.1.4.1.5
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Identifies the status of the shelf's fan tray. A controllerFailure(2) indicates that the fan status can not be obtained. In that case in can not be determined if the fans are operational, or experiencing other failures as well.
What is sonusNodeShelfStatFan?
The status of the shelf's fan tray; a controllerFailure(2) value specifically means the fan status itself couldn't be read, not that the fans are confirmed working or failed. An admin treats controllerFailure(2) as inconclusive and escalates to a hands-on check rather than assuming cooling is fine.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2879.2.1.1.1.1.4.1.5 snmpwalk -v2c -c public <target> SONUS-NODE-MIB::sonusNodeShelfStatFan
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2879.2.1.1.1.1.4.1.5.1 snmpget -v2c -c public <target> SONUS-NODE-MIB::sonusNodeShelfStatFan.1
Start monitoring Sonus Networks softswitch/media gateway node (shelf presence/power/management status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SONUS-NODE-MIB::sonusNodeShelfStatFan OID value, configure state conditions and alerts, and monitor any Sonus Networks softswitch/media gateway node (shelf presence/power/management status) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2879 | sonus | SONUS-SMI |
| 1.3.6.1.4.1.2879.2 | sonusMgmt | SONUS-SMI |
| 1.3.6.1.4.1.2879.2.1 | sonusSystemMIBs | SONUS-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2879.2.1.1 | sonusNodeMIB | SONUS-NODE-MIB |
| 1.3.6.1.4.1.2879.2.1.1.1 | sonusNodeMIBObjects | SONUS-NODE-MIB |
| 1.3.6.1.4.1.2879.2.1.1.1.1 | sonusNode | SONUS-NODE-MIB |
| 1.3.6.1.4.1.2879.2.1.1.1.1.4 | sonusNodeShelfStatTable | SONUS-NODE-MIB |
| 1.3.6.1.4.1.2879.2.1.1.1.1.4.1 | sonusNodeShelfStatEntry | SONUS-NODE-MIB |
| 1.3.6.1.4.1.2879.2.1.1.1.1.4.1.5 | sonusNodeShelfStatFan | SONUS-NODE-MIB |