All MIBs › SONUS-ISUP-SERVICE-GROUP-MIB › sonusIsupsgFarEndCircuitContinuityRequirement
sonusIsupsgFarEndCircuitContinuityRequirement
Module: SONUS-ISUP-SERVICE-GROUP-MIB
OID (symbolic): SONUS-ISUP-SERVICE-GROUP-MIB::sonusIsupsgFarEndCircuitContinuityRequirement
OID (numeric): 1.3.6.1.4.1.2879.2.6.1.1.6.1.7
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Continuity check requirements of the far end circuit group.
What is sonusIsupsgFarEndCircuitContinuityRequirement?
Reports whether the far-end switch expects no continuity checking none(2), only statistical(3) sampling, or a perCall(4) continuity test on every call for this circuit group. An admin compares this to the local sonusIsupsgServiceGroupContTestFreq setting to make sure both ends agree on how often COT is performed.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2879.2.6.1.1.6.1.7 snmpwalk -v2c -c public <target> SONUS-ISUP-SERVICE-GROUP-MIB::sonusIsupsgFarEndCircuitContinuityRequirement
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2879.2.6.1.1.6.1.7.1 snmpget -v2c -c public <target> SONUS-ISUP-SERVICE-GROUP-MIB::sonusIsupsgFarEndCircuitContinuityRequirement.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> sonusIsupsgFarEndCircuitContinuityRequirement.1
Start monitoring Sonus Networks softswitch, SS7 signaling gateway (ISUP point-code/routing configuration) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SONUS-ISUP-SERVICE-GROUP-MIB::sonusIsupsgFarEndCircuitContinuityRequirement OID value, configure state conditions and alerts, and monitor any Sonus Networks softswitch, SS7 signaling gateway (ISUP point-code/routing configuration) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2879 | sonus | SONUS-SMI |
| 1.3.6.1.4.1.2879.2 | sonusMgmt | SONUS-SMI |
| 1.3.6.1.4.1.2879.2.6 | sonusSignallingMIBs | SONUS-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2879.2.6.1 | sonusIsupServiceGroupMIB | SONUS-ISUP-SERVICE-GROUP-MIB |
| 1.3.6.1.4.1.2879.2.6.1.1 | sonusIsupServiceGroupMIBObjects | SONUS-ISUP-SERVICE-GROUP-MIB |
| 1.3.6.1.4.1.2879.2.6.1.1.6 | sonusIsupsgFarEndCircuitAdminTable | SONUS-ISUP-SERVICE-GROUP-MIB |
| 1.3.6.1.4.1.2879.2.6.1.1.6.1 | sonusIsupsgFarEndCircuitAdminEntry | SONUS-ISUP-SERVICE-GROUP-MIB |
| 1.3.6.1.4.1.2879.2.6.1.1.6.1.7 | sonusIsupsgFarEndCircuitContinuityRequirement | SONUS-ISUP-SERVICE-GROUP-MIB |