SONUS-ISUP-SERVICE-GROUP-MIB :: sonusIsupsgFarEndCircuitAlarmCarrier

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SONUS-ISUP-SERVICE-GROUP-MIB › sonusIsupsgFarEndCircuitAlarmCarrier

sonusIsupsgFarEndCircuitAlarmCarrier

Module: SONUS-ISUP-SERVICE-GROUP-MIB

OID (symbolic): SONUS-ISUP-SERVICE-GROUP-MIB::sonusIsupsgFarEndCircuitAlarmCarrier

OID (numeric): 1.3.6.1.4.1.2879.2.6.1.1.6.1.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Alarm carrier indicator of the far end circuit group.

What is sonusIsupsgFarEndCircuitAlarmCarrier?

Reports whether the far-end switch handles this circuit group's alarm carrier in software(2) or hardware(3), as returned by the far-end validation exchange. This is largely diagnostic information an admin cross-checks against local provisioning during interconnect troubleshooting.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2879.2.6.1.1.6.1.6
snmpwalk -v2c -c public <target> SONUS-ISUP-SERVICE-GROUP-MIB::sonusIsupsgFarEndCircuitAlarmCarrier

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2879.2.6.1.1.6.1.6.1
snmpget -v2c -c public <target> SONUS-ISUP-SERVICE-GROUP-MIB::sonusIsupsgFarEndCircuitAlarmCarrier.1

Start monitoring Sonus Networks softswitch, SS7 signaling gateway (ISUP point-code/routing configuration) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SONUS-ISUP-SERVICE-GROUP-MIB::sonusIsupsgFarEndCircuitAlarmCarrier OID value, configure state conditions and alerts, and monitor any Sonus Networks softswitch, SS7 signaling gateway (ISUP point-code/routing configuration) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2879sonusSONUS-SMI
1.3.6.1.4.1.2879.2sonusMgmtSONUS-SMI
1.3.6.1.4.1.2879.2.6sonusSignallingMIBsSONUS-SMI
Numeric OIDNameModule
1.3.6.1.4.1.2879.2.6.1sonusIsupServiceGroupMIBSONUS-ISUP-SERVICE-GROUP-MIB
1.3.6.1.4.1.2879.2.6.1.1sonusIsupServiceGroupMIBObjectsSONUS-ISUP-SERVICE-GROUP-MIB
1.3.6.1.4.1.2879.2.6.1.1.6sonusIsupsgFarEndCircuitAdminTableSONUS-ISUP-SERVICE-GROUP-MIB
1.3.6.1.4.1.2879.2.6.1.1.6.1sonusIsupsgFarEndCircuitAdminEntrySONUS-ISUP-SERVICE-GROUP-MIB
1.3.6.1.4.1.2879.2.6.1.1.6.1.6sonusIsupsgFarEndCircuitAlarmCarrierSONUS-ISUP-SERVICE-GROUP-MIB