SONUS-ALARM-CONTACT-MIB :: sonusAlarmOutAdmnShelfIndex

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SONUS-ALARM-CONTACT-MIB › sonusAlarmOutAdmnShelfIndex

sonusAlarmOutAdmnShelfIndex

Module: SONUS-ALARM-CONTACT-MIB

OID (symbolic): SONUS-ALARM-CONTACT-MIB::sonusAlarmOutAdmnShelfIndex

OID (numeric): 1.3.6.1.4.1.2879.2.1.6.1.1.1.1

Node type: OBJECT-TYPE

Type: SonusShelfIndex

Access: read-only

Description: Identifies the target shelf within the node.

What is sonusAlarmOutAdmnShelfIndex?

sonusAlarmOutAdmnShelfIndex is a read-only SonusShelfIndex that, as part of the table's index, identifies the target shelf within the node for an outbound alarm relay's administrative configuration. Admins use this to determine which physical shelf in a multi-shelf Sonus system a given alarm relay configuration row applies to. For example, in a node with shelves 1 and 2, an admin would filter on sonusAlarmOutAdmnShelfIndex to isolate the alarm relay settings for shelf 2 specifically.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2879.2.1.6.1.1.1.1
snmpwalk -v2c -c public <target> SONUS-ALARM-CONTACT-MIB::sonusAlarmOutAdmnShelfIndex

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2879.2.1.6.1.1.1.1.1
snmpget -v2c -c public <target> SONUS-ALARM-CONTACT-MIB::sonusAlarmOutAdmnShelfIndex.1

Start monitoring Sonus Networks (Ribbon Communications) media gateways/softswitches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SONUS-ALARM-CONTACT-MIB::sonusAlarmOutAdmnShelfIndex OID value, configure state conditions and alerts, and monitor any Sonus Networks (Ribbon Communications) media gateways/softswitches from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2879sonusSONUS-SMI
1.3.6.1.4.1.2879.2sonusMgmtSONUS-SMI
1.3.6.1.4.1.2879.2.1sonusSystemMIBsSONUS-SMI
Numeric OIDNameModule
1.3.6.1.4.1.2879.2.1.6sonusAlarmManagerMIBSONUS-ALARM-CONTACT-MIB
1.3.6.1.4.1.2879.2.1.6.1sonusAlarmManagerMIBObjectsSONUS-ALARM-CONTACT-MIB
1.3.6.1.4.1.2879.2.1.6.1.1sonusAlarmOutAdmnTableSONUS-ALARM-CONTACT-MIB
1.3.6.1.4.1.2879.2.1.6.1.1.1sonusAlarmOutAdmnEntrySONUS-ALARM-CONTACT-MIB
1.3.6.1.4.1.2879.2.1.6.1.1.1.1sonusAlarmOutAdmnShelfIndexSONUS-ALARM-CONTACT-MIB