All MIBs › SONUS-ALARM-CONTACT-MIB › sonusAlarmOutAdmnRelayIndex
sonusAlarmOutAdmnRelayIndex
Module: SONUS-ALARM-CONTACT-MIB
OID (symbolic): SONUS-ALARM-CONTACT-MIB::sonusAlarmOutAdmnRelayIndex
OID (numeric): 1.3.6.1.4.1.2879.2.1.6.1.1.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Identifies the target outbound relay within the shelf.
What is sonusAlarmOutAdmnRelayIndex?
sonusAlarmOutAdmnRelayIndex identifies the target outbound relay within the shelf, coded as shelfpwr, critical, major, minor, or user, and forms part of the table's index for an alarm relay's administrative configuration. Admins use this to distinguish which of the five predefined alarm relay types (e.g. critical vs. minor) a given configuration row governs. For example, an admin configuring how the shelf reports critical failures would look for the row with sonusAlarmOutAdmnRelayIndex set to critical-2(2).
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2879.2.1.6.1.1.1.2 snmpwalk -v2c -c public <target> SONUS-ALARM-CONTACT-MIB::sonusAlarmOutAdmnRelayIndex
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2879.2.1.6.1.1.1.2.1 snmpget -v2c -c public <target> SONUS-ALARM-CONTACT-MIB::sonusAlarmOutAdmnRelayIndex.1
Start monitoring Sonus Networks (Ribbon Communications) media gateways/softswitches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SONUS-ALARM-CONTACT-MIB::sonusAlarmOutAdmnRelayIndex OID value, configure state conditions and alerts, and monitor any Sonus Networks (Ribbon Communications) media gateways/softswitches from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2879 | sonus | SONUS-SMI |
| 1.3.6.1.4.1.2879.2 | sonusMgmt | SONUS-SMI |
| 1.3.6.1.4.1.2879.2.1 | sonusSystemMIBs | SONUS-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2879.2.1.6 | sonusAlarmManagerMIB | SONUS-ALARM-CONTACT-MIB |
| 1.3.6.1.4.1.2879.2.1.6.1 | sonusAlarmManagerMIBObjects | SONUS-ALARM-CONTACT-MIB |
| 1.3.6.1.4.1.2879.2.1.6.1.1 | sonusAlarmOutAdmnTable | SONUS-ALARM-CONTACT-MIB |
| 1.3.6.1.4.1.2879.2.1.6.1.1.1 | sonusAlarmOutAdmnEntry | SONUS-ALARM-CONTACT-MIB |
| 1.3.6.1.4.1.2879.2.1.6.1.1.1.2 | sonusAlarmOutAdmnRelayIndex | SONUS-ALARM-CONTACT-MIB |