OID (symbolic): SLEV2-EPON-IM-MIB::sleV2EponIMAlarmOnuAlarmIndex

OID (numeric): 1.3.6.1.4.1.6296.102.15.4.1.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Alarm type. err_frame_period - errored frame period alarm is raised when a threshold number of errored frame occur in the specified window time period. err_frame - errored frame alarm is raised when a threshold number of errored frames occur among the specified number of frames. err_frame_second - errored frame seconds summary alarm is raised when a threshold number of errored frames occur in the specified window time period. this alarm type is a summary of the errored frame period alarm.

What is sleV2EponIMAlarmOnuAlarmIndex?

Identifies the type of error-frame alarm this table row covers: errFramePeriod fires when a threshold number of errored frames occur within a specific time window, errFrame fires when a threshold fraction of errored frames occur among a specific number of frames received, and errFrameSecond is a summary alarm that fires when a threshold number of one-second intervals contain errored frames. An admin uses this to distinguish a rate-based alarm from a windowed count-based one when deciding how to tune sleV2EponIMAlarmOnuThreshold.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6296.102.15.4.1.1.2
snmpwalk -v2c -c public <target> SLEV2-EPON-IM-MIB::sleV2EponIMAlarmOnuAlarmIndex

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6296.102.15.4.1.1.2.1
snmpget -v2c -c public <target> SLEV2-EPON-IM-MIB::sleV2EponIMAlarmOnuAlarmIndex.1

Start monitoring DASAN Networks SLE v2 EPON OLT, EPON ONU endpoints (ONU registration/port-mapping status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SLEV2-EPON-IM-MIB::sleV2EponIMAlarmOnuAlarmIndex OID value, configure state conditions and alerts, and monitor any DASAN Networks SLE v2 EPON OLT, EPON ONU endpoints (ONU registration/port-mapping status) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6296dasanDASAN-DHCP-MIB
1.3.6.1.4.1.6296.102sleV2MgmtDASAN-SMI
Numeric OIDNameModule
1.3.6.1.4.1.6296.102.15sleV2EponIMSLEV2-EPON-IM-MIB
1.3.6.1.4.1.6296.102.15.4sleV2EponIMAlarmSLEV2-EPON-IM-MIB
1.3.6.1.4.1.6296.102.15.4.1sleV2EponIMAlarmTableSLEV2-EPON-IM-MIB
1.3.6.1.4.1.6296.102.15.4.1.1sleV2EponIMAlarmEntrySLEV2-EPON-IM-MIB
1.3.6.1.4.1.6296.102.15.4.1.1.2sleV2EponIMAlarmOnuAlarmIndexSLEV2-EPON-IM-MIB