All MIBs › SLE-SYNCE-MIB › sleSynceInputSourceControlSwitchType
sleSynceInputSourceControlSwitchType
Module: SLE-SYNCE-MIB
OID (symbolic): SLE-SYNCE-MIB::sleSynceInputSourceControlSwitchType
OID (numeric): 1.3.6.1.4.1.6296.101.93.4.2.7
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Description.
What is sleSynceInputSourceControlSwitchType?
This read-write value, used together with sleSynceInputSourceControlRequest (setSynceInputsourceSwitch), sets whether a manual switch to the input source named in sleSynceInputSourceControlIfIndex is cleared (clear(1)) or forced (manual(2)); an admin uses manual(2) to force the switch onto a specific timing source for testing or troubleshooting.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6296.101.93.4.2.7 snmpwalk -v2c -c public <target> SLE-SYNCE-MIB::sleSynceInputSourceControlSwitchType
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.6296.101.93.4.2.7.1 snmpget -v2c -c public <target> SLE-SYNCE-MIB::sleSynceInputSourceControlSwitchType.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.6296.101.93.4.2.7.1 i <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> sleSynceInputSourceControlSwitchType.1
Start monitoring DASAN Networks SLE-series OLT (Optical Line Terminal) (Synchronous Ethernet clock source/lock status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SLE-SYNCE-MIB::sleSynceInputSourceControlSwitchType OID value, configure state conditions and alerts, and monitor any DASAN Networks SLE-series OLT (Optical Line Terminal) (Synchronous Ethernet clock source/lock status) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.6296 | dasan | DASAN-DHCP-MIB |
| 1.3.6.1.4.1.6296.101 | sleMgmt | DASAN-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.6296.101.93 | sleSynce | SLE-SYNCE-MIB |
| 1.3.6.1.4.1.6296.101.93.4 | sleSynceInputSource | SLE-SYNCE-MIB |
| 1.3.6.1.4.1.6296.101.93.4.2 | sleSynceInputSourceControl | SLE-SYNCE-MIB |
| 1.3.6.1.4.1.6296.101.93.4.2.7 | sleSynceInputSourceControlSwitchType | SLE-SYNCE-MIB |